Service Modes, Error Codes, and Fault Finding
EN 31
BJ2.4U/BJ2.5U PA
5.
Figure 5-17 “Semi Stand-by” to “POD Stand-by” flowchart
G_15960_134.eps
100306
action holder: MIPS
autonomous action
action holder: St-by
POD standby
Semi Stand by
This state transition is entered when standby is requested
and an authenticated POD is present. When in semi-
standby, the CEservices will set the POD standby NVM
bit and ask infra to reboot. After the reboot, POD standby
will be entered. The Trimedia images are not started in
this case and CEsvc will ask infra to enter the Hardware
POD standby state.
Switch OFF all supplies which are not needed in POD
standby by switching HIGH the ON-MODE I/O line.
D8V6 supply detection algorithm
Reboot
Power-down HDMI and 1394 hardware by keeping
POWERDOWN-1394 GPIO 0 line high.
Set Viper HW blocks (TM1, TM2, MBS, VMSP1 and
VMSP2) to powerdown mode.
Hibernate the PNX2015 memory and keep the
PNX2015 in reset state
Disable audio protection algorithm