5 Installation instructions
4 Product structure
The installation for electrical and plumbing work must be operated by
qualified personnel, according to the installation instructions and in
compliance to the local authority regulations.
Unit has to be installed as near as possible to the service points, in order
to reduce heat loss along the pipes. To facilitate maintenance, allow a
distance of 50cm for easy access to the electrical parts.
This electrical water heater should be mounted on a solid cement wall,
preferably where it is close to the power source and water source.
Diagram 3
Diagram 3
Machine body
Machine body
Power indicator
Heating indicator
Heating indicator
Cold water inlet
Hot water outlet
Cold water inlet
Hot water outlet
Temperature
control knob
Temperature
control knob
AWH1110 AWH1111
AWH1120 AWH1121 AWH1122
AWH1121H/90 AWH1121B/90 AWH1122H/90 AWH1122B/90
02
2 Operating procedures
3 Product features
Ensure all the piping connection without leakage before turning on the
electric power of the heater.
Make sure that the tank is fully filled up with water, otherwise the heating
elements will be damaged.
Turn on the main electrical power supply and then adjust the temperature
knob clockwise for higher temperature and anti-clockwise for lower
temperature.
During the heating process, it's normal to see a slight drip at the safety
valve. Please do not cover up the safety valve outlet.
Connect this outlet with a discharge pipe. Water may drip from the pipe,
therefore please keep it exposed to the atmosphere.
The safety valve is to be released regularly (preferably at least every six
months) to remove lime deposit and to ensure that it is not blocked.
Unique profile.
Sapphire golden silicon tank which is rust-proof, erosion-proof and with
higher efficiency and having a longer life span.
Energy saving with minimum heat loss. The water temperature is able to
be maintained up to 48 hours after the electricity is switched off.