Toothbrush handle
1
Remove the brush head and rinse the metal shaft area with warm
water.
Do not push on the rubber seal on the metal shaft with sharp objects, as
this may cause damage.
2
Use a damp cloth to wipe the entire surface of the handle.
Brush head
1
Rinse the brush head and bristles after each use.
2
Remove the brush head from the handle and rinse the brush head
connection at least once a week with warm water.
charger
1
Unplug the charger.
2
Use a damp cloth to wipe the surface of the charger.
Sanitiser (specific types only)
Do not clean the sanitiser when the UV light bulb is hot.
For optimal effectiveness, it is recommended to clean the sanitiser weekly.
1
Unplug the sanitiser.
2
Pull the drip tray straight out. Rinse the drip tray and wipe it clean
with a damp cloth.
3
Clean all reflector surfaces with a damp cloth.
4
Remove the protective screen in front of the UV light bulb.
To remove the screen, grasp the edges next to the snaps, gently squeeze
and pull it out.
5
Remove the UV light bulb.
To remove the light bulb, grasp it and pull it out of the metal clasp.
6
Clean the protective screen and the UV light bulb with a damp cloth.
7
Reinsert the UV light bulb.
To reinsert the light bulb, align the bottom of the light bulb with the metal
clasp and push the bulb into the clasp.
8
Reinsert the protective screen.
EnglisH
11