background image

Power Requirements

5

Sixer Lighting Control Console

Installation & User’s Manual

INSTALLATION AND SET UP

1. Power Requirements

The Sixer Lighting Control Console operates on 9 volts DC. It is powered via its supplied AC to DC power supply
(for either 230/240 volt or 120 volt operation - depending on model). Also, the console can operate using a 9 volt
battery (not supplied).

2. Connecting a DMX512 Network

Basic DMX512 installation consists of connecting a Sixer Lighting Control Console to DMX512 controlled devices
in "daisy-chain" fashion. A cable runs from the Sixer Lighting Control Console to the DMX connector on the first
device to be controlled.

Note:  

For more information on DMX512 networking and systems, refer to  

"Additional Resources for DMX512" on 

page 1

. For Sixer Lighting Control Console DMX512 operation, refer to 

"OPERATION" on page 6

.

Note:  

It is recommended that control cable from the Sixer Lighting Console not be connected or disconnected when 

power is applied to the controlled devices. Doing so may cause any connected loads to flash up momentarily.

3. Using The Sixer Control Console

Setup and using your Sixer Lighting Console is simple:

1) Connect provided power supply to AC supply source and to Sixer Lighting Console 

OR

 insert a 9 volt 

battery (not supplied).

2) Connect DMX512 cable to Sixer Lighting Console and to device or devices to be controlled.

3) At Sixer Lighting Console Power Switch, turn ON console.

4) On Sixer Lighting Console, raise Channel Faders as desired to select the intensity for each channel.

5) On Sixer Lighting Console, use Grand Master to proportionally fade all channels.

1

2

3

4

5

DMX512 Connections

Note: Remaining pins on connector are not used.

DMX512 Signal

XLR Pin

Common (Drain)

1

DMX512 -

2

3

DMX512 Output 

(out to DMX512 

controlled device or devices)

End View

Содержание 75801

Страница 1: ......

Страница 2: ...ion seulement et est sujet à changements sans préavis La compagnie Philips Strand Lighting n assume aucune responsibilité sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises à jour de ce manuel veuillez s il vous plait contacter le bureau de Philips Strand Lighting le plus proche Note Information contained in this d...

Страница 3: ...ot mount near gas or electric heaters d Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel e The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition f Not for residential use Do not use this equipment for other than intended use g Refer service to qualified personnel SAVE THE...

Страница 4: ...PREFACE About this Manual 3 Getting Started 3 Unpack the Console 3 SIXER CONTROL CONSOLE OVERVIEW Sixer Lighting Control Console Components 4 Controls 4 Connections 4 INSTALLATION AND SET UP Power Requirements 5 Connecting a DMX512 Network 5 Using The Sixer Control Console 5 OPERATION Overview 6 Control Functions 6 Cleaning and Care Instructions 6 Troubleshooting Guide 6 TECHNICAL SPECIFICATIONS S...

Страница 5: ...tion and descriptions may be downloaded at www strandlighting com 2 Getting Started Unpack the Console Unpack the console from the packaging and check that the following components are contained within If any parts are missing or damaged please contact the carrier and your nearest Philips Strand Lighting office Sixer Console Components for 120V Markets catalog number 75801 Sixer Lighting Console A...

Страница 6: ... CONSOLE OVERVIEW 1 Sixer Lighting Control Console Components Controls Connections Channel Fader Slider 6 Each Grand Master Fader Slider LED Power Indicator 9V Battery Compartment Battery not supplied Front View DMX512 Output ON OFF Power Switch 9VDC Input Connector AC to DC power supply provided End View ...

Страница 7: ... operation refer to OPERATION on page 6 Note It is recommended that control cable from the Sixer Lighting Console not be connected or disconnected when power is applied to the controlled devices Doing so may cause any connected loads to flash up momentarily 3 Using The Sixer Control Console Setup and using your Sixer Lighting Console is simple 1 Connect provided power supply to AC supply source an...

Страница 8: ...mage the unit Being a solid state device the Sixer Lighting Console requires very little routine maintenance by the user Should the unit become dirty unplug from power supply or remove battery and clean unit using a lint free cleaning cloth If you have any questions regarding the use or care of your Sixer Lighting Console please contact Philips Strand Lighting technical support or your local Autho...

Страница 9: ...ly depends on model 120V or 230 240V Frequency 50 60Hz Output Signal DMX512 1990 Ambient Temperature 0 to 35 degrees C 32 to 95 degrees F Humidity 0 90 Non condensing Weight 1 0 kg 2 2 lbs Console only Dimensions Console 148 mm H x 166 mm W x 42 mm D 5 8 in H x 6 5 in W x 1 7 in D Compliance Provided Power Supply UL cUL listed Console CE Marked Note For complete model specifications features etc r...

Страница 10: ......

Отзывы: