background image

1

Sixer Lighting Control Console

Installation & User’s Manual

IMPORTANT INFORMATION

Warnings and Notices

Additional Resources for DMX512

For more information on installing DMX512 control systems, the following publication is available for purchase
from the United States Institute for Theatre Technology (USITT), "Recommended Practice for DMX512: A Guide
for Users and Installers,  2nd edition" (ISBN: 9780955703522). USITT Contact Information:

USITT
6443 Ridings Road
Syracuse, NY 13206-1111 USA
1-800-93USITT
www.usitt.org

Philips Strand Lighting Limited Two-Year Warranty

Philips Strand Lighting offers a two-year limited warranty of its products against defects in materials or
workmanship from the date of delivery. A copy of Philips Strand Lighting two-year limited warranty containing
specific terms and conditions can be obtained from the Philips Strand Lighting web site at www.strandlighting.com
or by contacting your local Philips Strand Lighting office.

When using electrical equipment, basic safety precautions should always be followed including the following:

a.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

.

b. For indoor, dry locations use only. Do not use outdoors.

c. Do not mount near gas or electric heaters.

d. Equipment should be mounted in locations and at heights where it will not readily be subjected to 

tampering by unauthorized personnel.

e. The use of accessory equipment not recommended by the manufacturer may cause an unsafe 

condition.

f. Not for residential use. Do not use this equipment for other than intended use.

g. Refer service to qualified personnel.

SAVE THESE INSTRUCTIONS

.

WARNING

: You must have access to a main circuit breaker or other power disconnect device 

before installing any wiring. Be sure that power is disconnected by removing fuses or turning the 
main circuit breaker off before installation. Installing the device with power on may expose you to 
dangerous voltages and damage the device. A qualified electrician must perform this installation.

WARNING

: Refer to National Electrical Code® and local codes for cable specifications. Failure to 

use proper cable can result in damage to equipment or danger to personnel.

WARNING

: This equipment is intended for installation in accordance with the National Electric 

Code® and local regulations. It is also intended for installation in indoor applications only. Before 
any electrical work is performed, disconnect power at the circuit breaker or remove the fuse to avoid 
shock or damage to the control. It is recommended that a qualified electrician perform this 
installation.

Содержание 75801

Страница 1: ......

Страница 2: ...ion seulement et est sujet à changements sans préavis La compagnie Philips Strand Lighting n assume aucune responsibilité sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises à jour de ce manuel veuillez s il vous plait contacter le bureau de Philips Strand Lighting le plus proche Note Information contained in this d...

Страница 3: ...ot mount near gas or electric heaters d Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel e The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition f Not for residential use Do not use this equipment for other than intended use g Refer service to qualified personnel SAVE THE...

Страница 4: ...PREFACE About this Manual 3 Getting Started 3 Unpack the Console 3 SIXER CONTROL CONSOLE OVERVIEW Sixer Lighting Control Console Components 4 Controls 4 Connections 4 INSTALLATION AND SET UP Power Requirements 5 Connecting a DMX512 Network 5 Using The Sixer Control Console 5 OPERATION Overview 6 Control Functions 6 Cleaning and Care Instructions 6 Troubleshooting Guide 6 TECHNICAL SPECIFICATIONS S...

Страница 5: ...tion and descriptions may be downloaded at www strandlighting com 2 Getting Started Unpack the Console Unpack the console from the packaging and check that the following components are contained within If any parts are missing or damaged please contact the carrier and your nearest Philips Strand Lighting office Sixer Console Components for 120V Markets catalog number 75801 Sixer Lighting Console A...

Страница 6: ... CONSOLE OVERVIEW 1 Sixer Lighting Control Console Components Controls Connections Channel Fader Slider 6 Each Grand Master Fader Slider LED Power Indicator 9V Battery Compartment Battery not supplied Front View DMX512 Output ON OFF Power Switch 9VDC Input Connector AC to DC power supply provided End View ...

Страница 7: ... operation refer to OPERATION on page 6 Note It is recommended that control cable from the Sixer Lighting Console not be connected or disconnected when power is applied to the controlled devices Doing so may cause any connected loads to flash up momentarily 3 Using The Sixer Control Console Setup and using your Sixer Lighting Console is simple 1 Connect provided power supply to AC supply source an...

Страница 8: ...mage the unit Being a solid state device the Sixer Lighting Console requires very little routine maintenance by the user Should the unit become dirty unplug from power supply or remove battery and clean unit using a lint free cleaning cloth If you have any questions regarding the use or care of your Sixer Lighting Console please contact Philips Strand Lighting technical support or your local Autho...

Страница 9: ...ly depends on model 120V or 230 240V Frequency 50 60Hz Output Signal DMX512 1990 Ambient Temperature 0 to 35 degrees C 32 to 95 degrees F Humidity 0 90 Non condensing Weight 1 0 kg 2 2 lbs Console only Dimensions Console 148 mm H x 166 mm W x 42 mm D 5 8 in H x 6 5 in W x 1 7 in D Compliance Provided Power Supply UL cUL listed Console CE Marked Note For complete model specifications features etc r...

Страница 10: ......