5

INSTALLATION

The LightPack LED Module can be mounted in a variety of configurations. Depending on
your requirements, choose one of the methods shown below. The LightPack LED Module can
be mounted vertically (recommended) or horizontally as required, however, to allow for
optimum convection cooling, the module cannot be mounted with the heatsink fins downward.

WARNING:  

A non-removable safety cable is supplied with the unit. The safety cable 

must be attached to a secure structure and may be required by local or national codes.

Wall Mounting

The LightPack LED Module can be mounted to a wall. Note that the wall mounts (with
screws) are included with unit. Wall anchoring hardware is by others. The unit must be
mounted with the heatsink fins up/down so the unit will dissipate heat properly. Mounting to
wall must comply with local and national codes.

Figure 2:  LightPack LED Module Wall Mounting

Pipe Mounting

The LightPack LED Module can be mounted on pipe or truss. Note that the pipe mount (with
screws) are included with unit. Clamps are sold separately or by others (See “Clamps” on
page 3 for ordering information). The unit must be mounted with the heatsink fins up/down so
the unit will dissipate heat properly. Mounting to pipe or truss must comply with local and
national codes.

Figure 3:  LightPack LED Module Pipe or Truss Mounting

Wall Mount Bracket (x2)

Note heatsink orientation.
Mount as shown for proper
cooling.

Bracket Mounting
Screws (x4)

Wall Mount Brackets*

Note heatsink orientation.
Mount as shown for proper
cooling.

Pipe Mount Bracket

Bracket Mounting
Screws (x4)

*As an option, you can reverse the wall
mount brackets and install them as shown
for storage purposes. If the wall mount
brackets are installed in this fashion, all
four mounting screws are used.

Содержание 71361

Страница 1: ......

Страница 2: ...rand Lighting n assume aucune responsibilité sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises à jour de ce manuel veuillez s ll vous plait contacter le bureau de Strand Lighting le plus proche Information contained in this document may not be duplicated in full or in part by any person without prior written appro...

Страница 3: ...quipment for other than intended use g Refer service to qualified personnel SAVE THESE INSTRUCTIONS WARNING You must have access to a main circuit breaker or other power disconnect device before installing any wiring Be sure that power is disconnected by removing fuses or turning the main circuit breaker off before installation Installing the device with power on may expose you to dangerous voltag...

Страница 4: ...t this Guide 3 ACCESSORIES 3 Clamps 3 DMX512 Termination 3 OVERVIEW 4 INSTALLATION 5 Wall Mounting 5 Pipe Mounting 5 CONNECTING POWER 6 CONNECTING DATA 6 DMX512 Connections 6 LED Luminaire Port Connections 6 SETTING MODES AND DMX512 ADDRESS 7 OPERATION 8 LightPack LED Controller Status LED Indicators 8 Focus Bump Button Operation 8 Luminaire Discovery 8 SPECIFICATIONS 9 ...

Страница 5: ...isconnect power at the circuit breaker or remove the fuse to avoid shock or damage to the control It is recommended that a qualified electrician perform this installation Observe the following precautions when installing operating or servicing the product Disconnect power before servicing Install in dry locations only DO NOT power module from a dimmed source Connect to standard power or mechanical...

Страница 6: ... exactly the right number of control channels needed An intensity channel set up option is also available to make your luminaires even easier to use and program CAUTION The LightPack LED Module is for use with specified LED luminaires only NOT FOR USE WITH SCROLLERS For luminaire types refer to SPECIFICATIONS on page 9 Figure 1 LightPack LED Module Overview 1 5 6 3 4 2 7 8 9 SIDE VIEW END VIEW END...

Страница 7: ...unit will dissipate heat properly Mounting to wall must comply with local and national codes Figure 2 LightPack LED Module Wall Mounting Pipe Mounting The LightPack LED Module can be mounted on pipe or truss Note that the pipe mount with screws are included with unit Clamps are sold separately or by others See Clamps on page 3 for ordering information The unit must be mounted with the heatsink fin...

Страница 8: ...uminaire Port Connections The LightPack LED Module supports the control of two LED luminaires through its two LED Luminaire ports To AC Power AC Input Wiring 230V Models Wire Color Description Brown Line Blue Neutral Green Yellow Ground AC Input Wiring 120V Models Wire Color Description Black Line White Neutral Green Ground DMX 5 Pin Connectors Pinout Pin Signal 1 Common Drain 2 DMX512 3 DMX512 4 ...

Страница 9: ... Mode and Intensity Channel for each connected luminaire Step 1 At Configuration Switch set Switch 4 to ON Step 2 At Configuration Switch set 8 16 Bit Mode and Intensity channel switches as desired Step 3 Set each DMX address dial to desired DMX512 address for first luminaire Step 4 Press and hold Focus Bump button until first luminaire flashes Step 5 Set each DMX address dial to desired DMX512 ad...

Страница 10: ... Module is set by default for RGBAW LED luminaire operation If you plug in an RGB or WW LED luminaire you will need to cycle through the Focus Bump button presses as described in Focus Bump Button Operation to return to the first color The LightPack LED Module can discover and set itself to control the type of connected luminaire To Discover the connected luminaire Step 1 Connect luminaire to Ligh...

Страница 11: ...2 lbs 1 9 kg DMX512 Connections DMX512 In Out thru Output Connections 2 power and data on each Temperature 32 to 122 F 0 to 50 C Humidity Range 5 to 95 Non condensing Standards Compliance ETL cETL listed and CE marked Figure 8 Dimensions C 9 62 in 244 35 mm SIDE VIEW 3 25 in 82 55 mm END VIEW DMX Connectors AC Input BOTTOM VIEW Accessory Mounting Points 2 50 in 63 50 mm 8 56 in 217 43 mm 4 17 in 1...

Страница 12: ...Installation Operation Guide LightPack LED Module 10 Part No 2 450226 010 ...

Отзывы: