The LightPack LED Module will power up when the AC power is connected. (NOTE: the
LightPack LED Module does not have a main on/off switch.)

The LightPack LED Module provides two LED status indicators and a Focus/Bump buttons.

LightPack LED Controller - Status LED Indicators

The two LEDs associated with each channel report various operating conditions.

Focus / Bump Button Operation

Once each luminaire has been set up, tap the Focus / Bump button once to turn on all of the
LEDs on the attached luminaire. Each successive Button tap will advance through each LED
color that the Luminaire offers. The final tap will turn the luminaire off.

Luminaire Discovery

The LightPack LED Module is set, by default, for RGBAW LED luminaire operation. If you
plug in an RGB or WW LED luminaire, you will need to cycle through the Focus / Bump
button presses (as described in “Focus / Bump Button Operation”) to return to the first color.
The LightPack LED Module can "discover" and set itself to control the type of connected
luminaire. 

To Discover the connected luminaire:

Step

1. Connect luminaire to LightPack LED Module. Note, LightPack LED Module must 

be powered.

Step

2. Press and hold Focus / Bump button for 5 seconds.

Step

3. The luminaire will flash through all colors and stop. 

Step

4. The LightPack LED Module is now set to connected RGB or WW luminaire.

Red LED

Green LED

Condition

On

Off

No DMX512 Communications

Off / On

On

Module is set to 100% by Focus / Bump button

Button Tap

RGBAW Luminaire

RGB Luminaire

WW Luminaire

1

All On

All On

All On

2

Red

Red

Warm  White

3

Green

Green

Cool White

4

Blue

Blue

Off

5

Amber

Off

6

White

7

Off

Содержание 71361

Страница 1: ......

Страница 2: ...rand Lighting n assume aucune responsibilité sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises à jour de ce manuel veuillez s ll vous plait contacter le bureau de Strand Lighting le plus proche Information contained in this document may not be duplicated in full or in part by any person without prior written appro...

Страница 3: ...quipment for other than intended use g Refer service to qualified personnel SAVE THESE INSTRUCTIONS WARNING You must have access to a main circuit breaker or other power disconnect device before installing any wiring Be sure that power is disconnected by removing fuses or turning the main circuit breaker off before installation Installing the device with power on may expose you to dangerous voltag...

Страница 4: ...t this Guide 3 ACCESSORIES 3 Clamps 3 DMX512 Termination 3 OVERVIEW 4 INSTALLATION 5 Wall Mounting 5 Pipe Mounting 5 CONNECTING POWER 6 CONNECTING DATA 6 DMX512 Connections 6 LED Luminaire Port Connections 6 SETTING MODES AND DMX512 ADDRESS 7 OPERATION 8 LightPack LED Controller Status LED Indicators 8 Focus Bump Button Operation 8 Luminaire Discovery 8 SPECIFICATIONS 9 ...

Страница 5: ...isconnect power at the circuit breaker or remove the fuse to avoid shock or damage to the control It is recommended that a qualified electrician perform this installation Observe the following precautions when installing operating or servicing the product Disconnect power before servicing Install in dry locations only DO NOT power module from a dimmed source Connect to standard power or mechanical...

Страница 6: ... exactly the right number of control channels needed An intensity channel set up option is also available to make your luminaires even easier to use and program CAUTION The LightPack LED Module is for use with specified LED luminaires only NOT FOR USE WITH SCROLLERS For luminaire types refer to SPECIFICATIONS on page 9 Figure 1 LightPack LED Module Overview 1 5 6 3 4 2 7 8 9 SIDE VIEW END VIEW END...

Страница 7: ...unit will dissipate heat properly Mounting to wall must comply with local and national codes Figure 2 LightPack LED Module Wall Mounting Pipe Mounting The LightPack LED Module can be mounted on pipe or truss Note that the pipe mount with screws are included with unit Clamps are sold separately or by others See Clamps on page 3 for ordering information The unit must be mounted with the heatsink fin...

Страница 8: ...uminaire Port Connections The LightPack LED Module supports the control of two LED luminaires through its two LED Luminaire ports To AC Power AC Input Wiring 230V Models Wire Color Description Brown Line Blue Neutral Green Yellow Ground AC Input Wiring 120V Models Wire Color Description Black Line White Neutral Green Ground DMX 5 Pin Connectors Pinout Pin Signal 1 Common Drain 2 DMX512 3 DMX512 4 ...

Страница 9: ... Mode and Intensity Channel for each connected luminaire Step 1 At Configuration Switch set Switch 4 to ON Step 2 At Configuration Switch set 8 16 Bit Mode and Intensity channel switches as desired Step 3 Set each DMX address dial to desired DMX512 address for first luminaire Step 4 Press and hold Focus Bump button until first luminaire flashes Step 5 Set each DMX address dial to desired DMX512 ad...

Страница 10: ... Module is set by default for RGBAW LED luminaire operation If you plug in an RGB or WW LED luminaire you will need to cycle through the Focus Bump button presses as described in Focus Bump Button Operation to return to the first color The LightPack LED Module can discover and set itself to control the type of connected luminaire To Discover the connected luminaire Step 1 Connect luminaire to Ligh...

Страница 11: ...2 lbs 1 9 kg DMX512 Connections DMX512 In Out thru Output Connections 2 power and data on each Temperature 32 to 122 F 0 to 50 C Humidity Range 5 to 95 Non condensing Standards Compliance ETL cETL listed and CE marked Figure 8 Dimensions C 9 62 in 244 35 mm SIDE VIEW 3 25 in 82 55 mm END VIEW DMX Connectors AC Input BOTTOM VIEW Accessory Mounting Points 2 50 in 63 50 mm 8 56 in 217 43 mm 4 17 in 1...

Страница 12: ...Installation Operation Guide LightPack LED Module 10 Part No 2 450226 010 ...

Отзывы: