Service Modes, Error Codes, and Fault Finding
EN 21
BJ2.4U/BJ2.5U LA
5.
Figure 5-6 “Off” to “Semi Stand-by” flowchart (part 1)
All I/O lines have a “high” default state:
- Assert the Viper reset.
- Sound-Enable and Reset-Audio should remain “high”.
- NVM power line is “high”, no NVM communication possible.
Off
Standby Supply starts running.
+5V2, 1V2Stb, 3V3Stb and +2V5D become present.
In case of PDP 3V3 Vpr to CPU PDP becomes present.
st-by µP resets
Stand-by or
Protection
Mains is applied
- Switch Sound-Enable and Reset-Audio “high”.
They are “low” in the standby mode if the
standby mode lasted longer than 2s.
Enable the +1V2 supply (ENABLE-1V2)
detect-5V
received within
2900 ms after POD-MODE
toggle?
No
Yes
ac5V supply detection algorithm
+12V error
detect-12VSW received within
2900 ms after POD-mode
toggle?
No
SP
ac12VSW supply
detection algorithm
Yes
+5V, +8V6, +12VS, +12VSW and Vsound are switched on
Switch “on” all supplies by switching LOW the POD-MODE
and the ON-MODE I/O lines.
Initialise I/O pins of the st-by µP, start keyboard scanning, RC
detection, P50 decoding. Wake up reasons are “off”.
If the protection state was left by short circuiting the
SDM pins, detection of a protection condition during
startup will stall the startup. Protection conditions in a
playing set will be ignored. The protection mode will
not be entered.
In case of FHP PDP: Switch PDPGO “low”
CPUGO (inverse of the stby I/O line POD-MODE) and PDPGO
are then both “low” and the PDP is in the “low power” mode.
Switching the POD-MODE
low in an FHP PDP set
makes the CPUGO go “high”
and starts the PDP CPU.
except in an FHP PDP Cold
Boot
FHP PDP Set?
Switch PDPGO high:
PDP should start: 5V, 8V6 and
12V are activated
Yes
No
+5V error
detect-5V
received within
2900 ms after PDPGO
toggle?
No
SP
SP
Yes
Switching the PDPGO “high”
will give a visual artefact and
should only be done if really
necessary.
Switching the POD-MODE and the
“on” mode “low” in an
SDI PDP set
makes the PDP supplies go to the
“on” mode.
Within 4 seconds, a
valid LVDS must be sent to the
display to prevent protection.
(valid for V3 version)
Wait 50ms and then start polling the detect-
5V, detect-8V6 and detect-12V every 40ms.
The availability of the supplies is checked through detect signals (delivered by
dedicated detect-IC's) going to the st-by µP. These signals are available for
+12V, +8V6, +5V, +1V2 and +2V5. A low to high transition of the signals should
occur within a certain time after toggling the standby line. If an observers is
detected before the time-out elapses, of course, the process should continue in
order to minimize start up time.
Start polling the detect-1V2 every 40ms
Switch “low” the NVM power reset line. Add a 2ms delay
before trying to address the NVM to allow correct NVM
initialization.
+8V6 error
detect-8V6 received
within 6300 ms after POD-mode toggle?
Startup shall not wait for this detection
and continue startup.
No
SP
No need to wait for the 8V6 detection at this point.
ac8V6 supply
detection algorithm
Yes
return
ECO Baby Jaguar??
Auto Protection
Line High??
Audio Error
Yes
Yes
No
F_15400_096a.eps
230606
To part B
To part B
autonomous action
action holder: St-by
action holder: MIPS
Only applicable for sets with CableCARD
TM
slot (POD)
*
*
*
*
*
*
*
Содержание 37-LCD 37PF9431D
Страница 38: ...Service Modes Error Codes and Fault Finding EN 38 BJ2 4U BJ2 5U LA 5 Personal Notes E_06532_012 eps 131004 ...
Страница 121: ...Circuit Diagrams and PWB Layouts 121 BJ2 4U BJ2 5U LA 7 Layout SSB Top Side Part 1 Part 1 G_15930_057a eps 120606 ...
Страница 122: ...122 BJ2 4U BJ2 5U LA 7 Circuit Diagrams and PWB Layouts Layout SSB Top Side Part 2 Part 2 G_15930_057a eps 120606 ...
Страница 124: ...124 BJ2 4U BJ2 5U LA 7 Circuit Diagrams and PWB Layouts Layout SSB Bottom Side Part 1 Part 1 G_15930_058a eps 120606 ...
Страница 125: ...Circuit Diagrams and PWB Layouts 125 BJ2 4U BJ2 5U LA 7 Layout SSB Bottom Side Part 2 Part 2 G_16290_058b eps 270106 ...
Страница 201: ...Revision List EN 201 BJ2 4U BJ2 5U LA 11 11 Revision List Manual xxxx xxx xxxx 0 First release ...