Service Modes, Error Codes, and Fault Finding
EN 28
Q552.2L LA
5.
2012-Mar-16
back to
div. table
How to Exit CSM
Press “MENU” (or "HOME") / “Back” key on the RC-transmitter.
5.3
Stepwise Start-up
When the TV is in a protection state due to an error detected by
stand-by software (error blinking is displayed) and SDM is
activated via shortcutting the SDM solder path on the SSB, the
TV starts up until it reaches the situation just before protection.
So, this is a kind of automatic stepwise start-up. In combination
with the start-up diagrams below, you can see which supplies
are present at a certain moment. Caution: in case the start-up
in this mode with a faulty FET 7U0X is done, you can destroy
all IC’s supplied by the +1V8 and +1v1, due to overvoltage (12V
on XVX-line). It is recommended to measure first the FET
7U0X or others FET’s on shortcircuit before activating SDM via
the service pads.
The abbreviations “SP” and “MP” in the figures stand for:
•
SP: protection or error detected by the Stand-by
Processor.
•
MP: protection or error detected by the MIPS Main
Processor.
Figure 5-3 Transition diagram
18770_250_100216.eps
100402
Active
Semi
St by
St by
Mains
on
Mains
off
GoToProtection
- WakeUp requested
- Acquisition needed
- Tact switch pushed
- stby requested and
no data Acquisition
required
- St by requested
- tact SW pushed
WakeUp
requested
Protection
WakeUp
requested
(SDM)
GoToProtection
Hibernate
- Tact switch pushed
- last status is hibernate
after mains ON
Tact switch
pushed
Содержание 32PFL7606D/78
Страница 54: ...Circuit Descriptions EN 54 Q552 2L LA 7 7 1 3 SSB Cell Layout 19110_052_110421 eps 110421 ...
Страница 64: ...IC Data Sheets EN 64 Q552 2L LA 8 8 5 Diagram 10 8 2 DC DC B03B TPS53126PW IC7U03 Block diagram ...
Страница 65: ...IC Data Sheets EN 65 Q552 2L LA 8 8 6 Diagram 10 8 5 DC DC B03E ST1S10PH IC 7UD0 Block diagram ST1S10PH ...
Страница 70: ...IC Data Sheets EN 70 Q552 2L LA 8 Personal Notes ...