1-7-5
T2221EA
9. Focus Adjustment
Purpose:
Set the optimum Focus.
Symptom of Misadjustment:
If Focus Adjustment is
incorrect, blurred images are shown on the display.
Note:
Focus VR --- FBT (Sub CBA),
FBT = Fly Back Transformer
1. Operate the unit more than 30 minutes.
2. Face the unit to the East and degauss the CRT
using a degaussing coil.
3. Input the monoscope pattern.
4. Adjust the Focus Control on the FBT to obtain a
clear picture.
10. H. Position Adjustment
Purpose:
To obtain correct horizontal position of
screen image.
Symptom of Misadjustment:
H. position may not be
properly displayed.
1. Enter the Service mode. (See page 1-7-1.)
Press [8] button on the remote control unit and
select H-P mode.
2. Input monoscope pattern.
3. Press [CH.
o
/
p
] buttons on the remote control
unit so that the left and right side of the
monoscope pattern are equal to each other.
11. V. Shift Adjustment
Purpose:
To obtain correct vertical position of screen
image.
Symptom of Misadjustment:
If V. position is
incorrect, vertical position of image on the screen may
not be properly displayed.
1. Enter the Service mode. (See page 1-7-1.)
Press [9] button on the remote control unit and
select V-P mode. (Press [9] button then display will
change to V-P and V-S).
2. Input monoscope pattern.
3. Press [CH.
o
/
p
] buttons on the remote control
unit so that the top and bottom of the monoscope
pattern are equal to each other.
12. V. Size Adjustment
Purpose:
To obtain correct vertical height of screen
image.
Symptom of Misadjustment:
If V. Size is incorrect,
vertical height of image on the screen may not be
properly displayed.
1. Enter the Service mode. (See page 1-7-1.)
Press [9] button on the remote control unit and
select V-S mode. (Press [9] button then display will
change to V-P and V-S).
2. Input monoscope pattern.
3. Press [CH.
o
/
p
] buttons on the remote control
unit so that the monoscope pattern is 90
±
5% of
display size and the circle is round.
Test Point
Adj. Point
Mode
Input
---
Focus Control
---
Monoscope
Tape
M. EQ.
Spec.
---
Pattern Generator
See below
Test Point
Adj. Point
Mode
Input
---
[CH.
o
/
p
]
buttons
---
Monoscope
Tape
M. EQ.
Spec.
---
Pattern Generator
---
Test Point
Adj. Point
Mode
Input
---
[CH.
o
/
p
]
buttons
---
Monoscope
Tape
M. EQ.
Spec.
---
Pattern Generator
---
Test Point
Adj. Point
Mode
Input
---
[CH.
o
/
p
]
buttons
---
Monoscope
Tape
M. EQ.
Spec.
---
Pattern Generator
90
±
5%
Содержание 24MC4306/37
Страница 14: ...1 5 2 T2221IB ...
Страница 15: ...1 5 3 T2221IB ...
Страница 16: ...1 5 4 T2221IB ...
Страница 104: ...1 18 2 T2221PEX FRONT S4 S1 X1 Tape S3 S6 S15 S7 S2 Packing Tape X4 X2 1 X25 X26 X27 X3 X2 2 X2 3 X9 Packing ...
Страница 124: ...2 4 9 N2466FTDA 43 41 42 L 13 Fig DM16 44 45 Slide P 9 Fig DM17 ...
Страница 131: ...REVISION LIST Version 1 0 Original Release Version 1 1 Correction of pages 1 7 1 and 1 7 2 high lighted in Red ...