1-7-2
T2221EA
2. Setting for CONTRAST, COLOR,
TINT, V-TINT and SHARP Data
Values
General
1. Enter the Service mode. (See page 1-7-1.)
2. Press [PICTURE] button on the service remote
control unit. Display changes “BRT,” “CNT,” “COL,”
“TNT,” “V-T,” and “SHP” cyclically when [PICTURE]
button is pressed.
CONTRAST (CNT)
1. Press [PICTURE] button on the service remote
control unit. Then select “CONTRAST (CNT)”
display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “CONTRAST
(CNT)” becomes
90.
COLOR (COL)
1. Press [PICTURE] button on the service remote
control unit. Then select “COLOR (COL)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “COLOR (COL)”
becomes 58.
TINT (TNT)
1. Press [PICTURE] button on the service remote
control unit. Then select “TINT (TNT)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “TINT (TNT)”
becomes
55.
V-TINT (V-T)
1. Press [PICTURE] button on the service remote
control unit. Then select “V-TINT (V-T)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “V-TINT (V-T)”
becomes
55.
SHARP (SHP)
1. Press [PICTURE] button on the service remote
control unit. Then select “SHARP (SHP)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “SHARP (SHP)”
becomes
48.
Note: BRIGHT
data value does not need to be
adjusted because this setting is performed in
other setting.
3. H f0 Adjustment
Purpose:
To get correct horizontal position and size of
screen image.
Symptom of Misadjustment:
Horizontal position and
size of screen image may not be properly displayed.
Note:
R2583 --- Sub CBA
1. Connect frequency counter to R2583.
2. Operate the unit for at least 20 minutes.
3. Enter the Service mode. (See page 1-7-1.) Press
[2] button on the remote control unit and select H-
ADJ mode.
4. Press [CH.
o
/
p
] buttons on the remote control
unit so that the display will change “0” to “7.”
5. At this moment, choose display “0” to “7” when the
frequency counter display is closest to 15.734 kHz
±
300 Hz.
Test Point
Adj. Point
Mode
Input
R2583
[CH.
o
/
p
] buttons
Video
---
Tape
M. EQ.
Spec.
---
Frequency Counter 15.734 kHz
±
300 Hz
Содержание 24MC4306/37
Страница 14: ...1 5 2 T2221IB ...
Страница 15: ...1 5 3 T2221IB ...
Страница 16: ...1 5 4 T2221IB ...
Страница 104: ...1 18 2 T2221PEX FRONT S4 S1 X1 Tape S3 S6 S15 S7 S2 Packing Tape X4 X2 1 X25 X26 X27 X3 X2 2 X2 3 X9 Packing ...
Страница 124: ...2 4 9 N2466FTDA 43 41 42 L 13 Fig DM16 44 45 Slide P 9 Fig DM17 ...
Страница 131: ...REVISION LIST Version 1 0 Original Release Version 1 1 Correction of pages 1 7 1 and 1 7 2 high lighted in Red ...