90 Meridian 3
Measurement power Saving.
measurement of
power saving.pdf
Power consumption
measure the way -090
VGA Display identification
In accordance with VESA Display Channel Standard Ver.1.0 and DDC 2B capability
DVI Display identification
In accordance with DVI requirement (DDWG digital Visual Interface revision 1.0)
use DDC-2B, DDC/CI, and EDID V1.3
DDC /CI Support and Smart Manage/Control
In accordance with VESA DDC/CI and MCCS ver.2.0, the monitor should be workable with ,
Philps SmartManage, SmartControl V6.1, and Protrait Display Tune at least.
Hot-key definition
PerfectTune II
(formerly FGA, FACTORY GAMMA Alignment)
A. PerfectTune must be done after warming 30 minutes at least.
B. PerfectTune must be performed after Auto Color.
C. PerfectTune must be conducted through DVI or scaler embedded patterns.
D. Delta E < 2.5
audio
3.17.1 Frequency Response
The amplifier and speaker combination shall provide a frequency response of 300 Hz
to 20 kHz, with +/- 3 dB variation over the entire response range.
3.17.2 Total Harmonic Distortion
Total harmonic distortion shall be limited to 5% THD at the maximum wattage
speaker rating specified in section 1.3, at 1 kHz, when the input is 1.0Vrms.
3.17.3 Power Handling
Each speaker transducer shall accept up to the specified Wattage of audio power
without damage or exceeding the frequency response and total harmonic distortion
specifications.
3.17.4 Audio Amplifier
The amplifier shall provide two channels of audio up to 1.5 Watts per channel from
100 Hz
to 20 kHz, based upon an audio signal input of 1.0V RMS per channel.
3.17.5 Volume Control
For monitors with a manual volume control, the direction (at the bottom) of the bezel
volume control is “-“ key for Minimum volume and “+” key for Maximum volume. The
default shipping position of the Volume Control shall be approximately 90%.
3.17.6 Speaker Sensitivity
The speakers shall support a minimum sensitivity of 75 dB +/- 3 dB at 2W/1m at 1 kHz.
Содержание 246V5LAB/00
Страница 5: ...5 Meridian 3 1 Monitor Specifications Technical specifications ...
Страница 9: ...9 Meridian 3 Connecting to your PC ...
Страница 39: ...39 Meridian 3 9 Scaler Board Overview DC DC FFC Cable Scaler IC Flash ROM DVI EEPROM D SUB EEPROM ...
Страница 53: ...53 Meridian 3 6 Load the F W you want to upgrade 7 Start to program Click Auto to start programming ...
Страница 54: ...54 Meridian 3 8 Programing success There will be the message in the red frame after successful programming ...
Страница 59: ...59 Meridian 3 13 4 Run the ISP tool 1 Double click the icon to open the tool 2 Select the EDID folder ...
Страница 82: ...82 Meridian 3 Service Kit Description Part No Picture ISP TOOL 715GT089 B C EDID TOOL 715GT034 B ...