49
Meridian 3
6. Click the “Program” to start programming after monitor power on. When it shows “
Analog: PASS!, SN write OK!
and DVI: PASS!
”. The EDID and SN writing process are finished.
13.5 Check the SN
1. Connect the video source and power on monitor.
2. Press the “MENU” button to enter the user menu, and then check the 14 digital SN.
3. If this SN number is the same as what we had written by EDID tool, the EDID and SN writing is completed finally
Содержание 227E3QSU/69
Страница 26: ...26 Meridian 3 ...
Страница 31: ...31 Meridian 3 9 Scaler Board Overview Scaler IC DC DC Flash ROM DVI EEPROM VGA EEPROM FFC Connector ...
Страница 39: ...39 Meridian 3 Click Finish to complete the USB serial port driver installation ...
Страница 42: ...42 Meridian 3 6 Load the F W you want to upgrade 7 Start to program Click Auto to start programming 1 2 3 ...
Страница 56: ...56 Meridian 3 15 Monitor Exploded View ...