118 Meridian 3
6.1 Susceptibility of display to external environment
Operating
- Temperature:
0 to 40 degree C
-
Humidity:
80%
max
-
Altitude:
0
-3658
ft
- Air pressure:
600-1100 mBAR
Storage
- Temperature:
-20 to 60 degree C
-
Humidity:
95%
max
- Altitude:
0 -12192ft
- Air pressure:
300-1100 mBAR
Note
: recommend at 5 to 35
q
C, Humidity less than 60%.
6.2 Transportation tests
Refer to 5.15.2
6.3 Display disturbances from external environment
According to IEC 801-2 for ESD disturbances
6.4 Display disturbances to external environment
7. Reliability
7.1 Mean Time between Failures
System MTBF (Including the LCD panel and CCFL): 50,000 hrs
8. Quality Assurance Requirements
8.1 Acceptance test
According to MIL-STD-1916D Control II level
AQL: NA
(Please also refer to annual quality agreement)
Customer acceptance criteria: UAW0377/00
9. Philips’ Flat Panel Monitors Pixel Defect Policy
Philips’ Flat Panel Monitors Pixel Defect Policy
Bright Dot Defects
Acceptable Level
MODEL
221P3
1 lit sub-pixel
3
2 adjacent lit sub-pixels
1
3 adjacent lit sub-pixels (one white pixel)
0
Distance between two bright dots
15mm
Содержание 221P3LPYEB/00
Страница 15: ... 15 Meridian 3 5 Block Diagram 5 1 Scaler Board ...
Страница 33: ...33 Meridian 3 Remark Parts position can be searched by using FIND function in PDF ...
Страница 43: ...43 Meridian 3 CN751 CN002 CN004 CN752 CN755 CN756 From CN903 From CN603 USB Board ROCKER SW ...
Страница 44: ... 44 Meridian 3 9 Scaler Board Overview Scaler IC DC DC Flash ROM DVI EEPROM VGA EEPROM FFC Cable ...
Страница 53: ...53 Meridian 3 Click Finish to complete the USB driver installation ...
Страница 74: ... 74 Meridian 3 15 Monitor Exploded View ...