59
Meridian 3
14. White Balance, Luminance Adjustment
1. Apparatuses and program:
analyzer CA-210, PC, tool, FGA adjustment program (Philips LEDFGA.DDCI),
Pattern generator.
2. Equipment installation:
a. Connect analyzer CA-210 to PC by USB connector, install drive program CA-SDK Ver4.00 for CA-210 and restart
PC after finish installing
b. Install Port95NT drive program, set PC printer connector mode as ECP mode and reset PC after finish installing.
c. Connect tool as follow:
Note: It’s not necessary to connect Port 2.
3. Adjustment
Preparation before adjustment:
a. Monitor should be warmed up for more than half an hour.
b. Make sure that the tools are connected right and drive programs have been installed OK.
4. Adjustment process:
a. Press the power of CA-210, shut off the lens, press 0-Cal and open the lens after analyzer reset.
b. Open white balance adjustment program, select the right parameter according with the program and click OK.
c. Make sure that the lens of CA-210 aims at the center of the screen, then click START to adjust.
d. After finish adjusting, the adjustment program displays pass, and the START button changes for NEXT, which
means that you can adjust another monitor.
To PC LPT
To BSG-265A or
equivalent instrument
To PC Port 2
Philips model
Содержание 220B4LPCB/00
Страница 5: ... 5 Meridian 3 1 Monitor Specifications Technical specifications ...
Страница 15: ... 15 Meridian 3 5 Block Diagram 5 1 Scaler Board ...
Страница 34: ... 34 Meridian 3 9 Scaler Board Overview Scaler IC DC DC Flash ROM FFC Cable EEPROM ...
Страница 37: ...37 Meridian 3 2 The power board 3 The main board 4 The USB board ...
Страница 43: ...43 Meridian 3 ...
Страница 46: ... 46 Meridian 3 4 Configuration for ISP tool Tick FTDI 5 Load the F W you want to upgrade ...
Страница 61: ...61 Meridian 2 15 Monitor Exploded View ...
Страница 63: ...Meridian 3 63 Service Kit Description Part No Picture ISP TOOL 715GT089 B C EDID TOOL 715GT034 B ...