49
Meridian 3
12.5 Troubleshooting
1. “CheckSum Comparing Fail!” error.
Method: Tick the “Send MX2060 CMD” at Option item.
2.When can’t upgrade, please retry below several ways to upgrade.
(1) When the tool appears erase error, you can change another version tool to try.
(2) The p
rogram must be in the monitor standby state, while the fail communication with monitor might result the
monitor power off. In this situation, you may AC off the monitor for a while and then AC on to retry. Maybe the
defect will be cured.
(3) Change ISP JIG or cable.
(4) Change PC