51
Meridian 2
12. ISP Instruction
Note: Take the 201B2 ISP SOP for example (the 201BL2’s SOP is almost the same as 201B2)
When do the parts, need the tools as follow:
A. An i486 (or above) personal computer or compatible.
B. Microsoft operation system Windows 95/98/2000/XP.
C. “PORT95NT.exe” and “ISP_Tool V4.533.exe” programs
D. ISP Board (715GT034-B) x1, Printer cablex1, VGA cable x1
E. software
12.1 Double Click
to install the “PORT95NT.exe”, and then restart the computer.
12.2. Connect the ISP board as follow:
Note:
a. When update, should make sure the LCD AC on, DC off.
b. If the monitor can power on, enter into the factory mode to record the ADC value before programming.
After programming, check if the ADC value is changed, if it’s, you must change it to the value you
recorded before programming, finally press “Exit” to save.
c. If the monitor can’t be power on, after programming, switch the source to “Gray” or “black and white”
pattern and VGA mode, then do “Auto Color/Level”.
12.3 The process of ISP writing as follows:
Connect to
the PC LPT
DC 12V Input
Connect this port to the
Philips model VGA port