![Philips 14PV360 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/philips/14pv360/14pv360_service-manual_323163019.webp)
1-6-1
Z11PALEA
ELECTRICAL ADJUSTMENT INSTRUCTIONS
General Note:
"CBA" is abbreviation for "Circuit Board
Assembly."
NOTE:
Electrical adjustments are required after replacing
circuit components and certain mechanical parts.
It is important to perform these adjustments only
after all repairs and replacements have been com-
pleted.
Also, do not attempt these adjustments unless the
proper equipment is available.
Test Equipment Required
1. PAL Pattern Generator (Color Bar W/White Win-
dow, Red Color, Dot Pattern, Gray Scale,
Monoscope, Multi-Burst)
2. AC Milli Voltmeter (RMS)
3. Alignment Tape (FL6A), Blank Tape
4. DC Voltmeter
5. Oscilloscope: Dual-trace with 10:1 probe,
V-Range: 0.001~50V/Div,
F-Range: DC~AC-60MHz
6. Frequency Counter
7. Plastic Tip Driver
How to Set up the Service mode:
NOTE:
After replacing the IC202 ( Memory ) or Main CBA,
the set value in IC202 ( Memory ) will be lost. So it
is necessary to set up or adjust in the Service
mode after its replacement.
Service Mode:
1. Turn the power on. (Use main power on the TV
unit.)
2. Press [STANDBY/ON], [2], [7], [1], and [MUTE] but-
tons on the remote control unit in that order within 5
seconds.
-
To cancel the service mode, press [STANDBY/ON]
button on the remote control.
How to set up the option code
1. Enter the Service mode.
2. Press the [STATUS/EXIT] button on the remote
control unit. The option code appears on the dis-
play.
3. If needed, input the option code as shown below
using number buttons on the remote control unit.
4. To reset the software, press [PAUSE] and [5] but-
tons on the remote control unit.
The option code is changed.
1. DC 105V (+B) Adjustment
Purpose:
To obtain correct operation.
Symptom of Misadjustment:
The picture is dark and
unit does not operate correctly.
Note:
TP503(+B), TP504(GND), VR601 --- H.V./Power
Supply CBA
1. Connect the unit to AC Power Outlet.
2. Input a color bar signal from RF input and leave it
for at least 20 minutes.
Enter the Service mode. (See page 1-6-1.)
3. Connect DC Volt Meter to TP503(+B) and
TP504(GND).
4. Adjust VR601 so that the voltage of TP503(+B)
b105
±
0.5V DC.
Model
Option Code
14PV360(365)/01
133566
14PV360(365)/07
133564
14PV360(365)/39
133565
14PV365/58
133567
Test point
Adj. Point
Mode
Input
TP503
(+B)
TP504
(GND)
VR601
---
Color
Bar
Tape
M. EQ.
Spec.
---
DC Voltmeter
Plastic Tip Driver
+105
±
0.5V DC
Содержание 14PV360
Страница 33: ......
Страница 41: ...GND TP504 B TP503 B ADJ VR601 H Adjustment R583 BT6300F01021 A 1 8 33 1 8 34 H V Power Supply CBA Top View ...
Страница 42: ...PIN 5 OF CN571 WF13 Q571 Collector WF12 BT6300F01021 A 1 8 35 1 8 36 H V Power Supply CBA Bottom View ...
Страница 70: ...1 15 3 T6300PEX Packing TAPE TAPE TAPE TAPE X5 S6 X1 TAPE TAPE S4 X2 X4 X3 S3 S1 FRONT S2 ...
Страница 86: ...2 4 6 T6300DA S 12 19 Cap Belt Fig DM11 Fig DM12 20 C 1 21 ...
Страница 95: ......