![philippi ACE 12V/25A Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/philippi/ace-12v-25a/ace-12v-25a_user-manual_1538034027.webp)
26
3.3.2.
Setting according to the batteries type
Switches setting
Description of the
battery type
Voltage* U1
Charging
Voltage* U2
Floating
Maximum
duration of
BOOST (I)
Max. duration of
ABSORPTION
(U1)
A
B
C
D
0
0
0
0
Opened type bat
free electrolyte (wet)
14.1V
13,4V
6H
6H
1
0
0
0
Classic sealed type
bat
(Sealed Lead)
14.4V
13,8V
6H
6H
FACTORY SETTING
0
1
0
0
GEL type bat
14.4V
13,8V
6H
6H
1
1
0
0
AGM type bat**
14.4V
13,6V
6H
6H
0
0
1
0
Spiral type bat
14.4V
13,6V
6H
6H
1
0
1
0
Tin calcium lead bat
15.1V
14.4V
6H
6H
0
1
1
0
Wintering or standby
sealed bat
13.4V
13.4V
0H
0H
1
1
1
0
Stabilized DC power
supply
12.0V
12.0V
0H
0H
0
0
0
1
SPE1 open type bat
14.8V
13,2V
6H
6H
0
1
1
1
BUS CAN COMMUNICATION
1
1
1
1
PBUS CAN COMMUNICATION (ACE-PBUS or ACE-TFT)
(*) Voltage on + BAT 1, + BAT 2 and + BAT E with 10% of the rated current and a tolerance of +/- 1%.
(
**
)
REFRESH is not advised for certain types of AGM batteries
Some specific settings are possible – please consult us.
3.3.3.
Temperature compensation
The TEMP-AL sensor enables the compensation of Absorption voltage and
Floating Voltage depending on the ambient temperature of the battery room.
The adopted coefficient is -18mV/°C.