20
1.2.
W
ARRANTY
The manufacturer disclaims the warranty and philippi waives any liability whatsoever if the installation rules and
instructions for use are not observed.
The warranty is valid for 36 months. It covers parts and labour for equipment returned to the philippi plant
(Germany). Only original parts recognized as being defective will be replaced under the warranty.
Our warranty does not cover :
1.
Failure to abide by this manual
2.
Any mechanical, electrical or electronic alterations to the appliance
3.
Improper use
4.
Presence of moisture
5.
Failure to comply with AC power-supply tolerances (i.e. overvoltage)
6.
Incorrect connections
7.
Falls or impacts during transportation, installation or use
8.
Repairs carried out by anyone unauthorized by philippi
9.
The maintenance in the energy conversion area made by a non-authorized person by philippi
10.
Connection of any interface not supplied by philippi
11.
The cost of packaging and carriage
12.
Apparent or latent damage sustained during shipment and/or handling (any such claims should be sent to
the haulier)
Our warranty on no account provides for any form of compensation. philippi shall not be held liable for damage
incurred as a result of using the battery charger.
2.
OPERATING – PRESENTATION - INTERFACES
2.1.
O
PERATING PRINCIPLE
The design of the battery chargers in the ACE range is based on a high-frequency split converter that transforms the
AC signal into regulated and filtered DC current. They can operate as a DC power supply.
Once the type of battery and type of charge has been selected, operation of the battery charger is entirely automatic
(unless otherwise specified by the supplier or the manufacturer of the batteries). It can remain connected to the
batteries and does not need to be disconnected when starting up an engine (marine application), because it is
equipped with an integrated separator.
The appliance's output voltage is sufficient to recharge 1, 2 or separate 3 batteries (integrated charge distributor,
separation of batteries). The charger's maximum output is the rated current distributed to each output according to
the connected batteries banks.
Each output can deliver the rated current.
Not all the outputs have to be connected. However, if only one output is used, we recommend interconnecting
oBAT1, +BAT2 and +BATE to one another (optional).