background image

Tank-Monitor VTM 

 

 

 
REV 1A – FEB 2020 - Software Version 1.0 

page 5 

3.2. Electrical connection 

The  voltage  measurement  to  indicate  2 
battery  voltages  is  carried  out  for  the  first 
battery  via  the  +  terminal  (12/24V)  of  the 
supply 

voltage. 

The 

second 

voltage 

measurement  is  carried  out  on  the  Batt.2+ 
terminal

 
 
 
 
 
Up  to  four  tanks  can  be  monitored 
simultaneously. 
However, if fewer tanks are monitored, the first 
fuel gauge will be connected starting at port TG 
1 (for example, with 2 tankers, only ports TG 1 
and TG 2 will be used). 
 
Resistive sensors (e.g., TGT / TGW) and active 
tank sensors (e.g., TDS pressure probes) may be 
connected in mixed form. 
 
The  connection  is  made  according  to  the 
adjacent diagram 
 
A DFS flow sensor can only be connected to DFS 
(DFS + / Minus / DFS S)! 
 
ATTENTION: 
If the power supply (red line) of the ultrasonic 
sensor  or  the  pressure  sensor  TDS  does  not 
take place via the VTM, but directly via the DC 
on-board  network,  the  supply  line  must  be 
fused with a 1A fuse! 
 
The  minus  lines  of  the  tank  sensors  must  be 
connected  to  the  minus  (-)  terminal  to  avoid 
incorrect measurements. 
 
 
 
 
 

Содержание 071004010

Страница 1: ... you for buying the Tank Monitor VTM This digital unit is state of the art in Tank monitoring On the large illuminated display you can read the voltage of up to 2 additional batteries the current filling levels of up to 4 tanks and have the opportunity You recognize at a glance to set an alarm threshold for each tank full or empty alarm to set an alarm threshold for each voltage low and high level...

Страница 2: ...ater only Please use for deeper tanks up to 200 cm and very precise measurements the pressure sensor TDS200 water diesel grey black water or TDN200 water However these sensors are not included in the scope of delivery Sensors from other manufacturers can also be connected The Monitor is configured In SETUP to the connected sensors It is also possible to adapt it to the tank geometry in order to di...

Страница 3: ...quids spilled into the device or oxidation due to condensation Lightning strike Not covered by the warranty are consequential costs and natural wear When asserting claims under warranty and warranty a detailed description of the defect is essential Detailed instructions facilitate and speed up the processing Please understand that we cannot accept shipments that are not free 1 4 Disclaimer Both th...

Страница 4: ...ting instructions are part of the component delivery It must well important for subsequent maintenance well kept and passed on to any subsequent owners of the device 3 Installation 3 1 Monitor Install the monitor in a protected dry and well visible place so that it can be read at any time The cut out is 85 x 85 mm the required minimum depth is 35mm On the back side there is a 3 pin terminal for th...

Страница 5: ...ng at port TG 1 for example with 2 tankers only ports TG 1 and TG 2 will be used Resistive sensors e g TGT TGW and active tank sensors e g TDS pressure probes may be connected in mixed form The connection is made according to the adjacent diagram A DFS flow sensor can only be connected to DFS DFS Minus DFS S ATTENTION If the power supply red line of the ultrasonic sensor or the pressure sensor TDS...

Страница 6: ...mation OK will take you to the settings menu The following settings can be made by pressing the respective symbol 1 Display settings 3 Battery settings 4 Alarm settings 5 Tank settings 4 2 Display After pressing the Display symbol the adjacent image appears The following settings can now be made Language EN FR GB Brightness max 20 100 Brightness Auto ON OFF Auto stand by OFF x s min Change PIN Num...

Страница 7: ...f the level rises above the set value an alarm is triggered The alarm is delayed by 15s Battery voltage alarms If a voltage 8V is present at the shunt at the terminal 2 for the 2nd battery voltage this is reported as another battery If the battery voltage drops or exceeds the set threshold value for 20 s an alarm can be generated The following settings are possible in the alarm menu Optical alarm ...

Страница 8: ... the resistance values for these levels at the push of a button The same applies to tank sensors with a voltage output sensor type User U For the sensor type UTV 40 80 the tank depth is entered in this menu These settings are saved in the event of a power failure and are available again after restarting 4 4 1 Tank type For each tank there are 5 different tank symbols to choose from Water Diesel Ga...

Страница 9: ...s empty 33 ohms full In the TRIM menu the characteristic curve of the fuel gauge can be adapted to the tank geometry 4 4 3 4 Sensor type User R For this setting you need a passive fuel gauge with any resistance range between 1 1000 ohms For the levels 0 25 50 75 and 100 the corresponding resistance values must now be entered in the TRIM menu Tank sensor This setting only works with passive resista...

Страница 10: ...respective tank in the main menu Since this sensor can not detect whether the tank is being filled you must enter the fill level manually By pressing the assigned key you can go directly to the tank menu and adjust the level accordingly If water flows through the flow sensor DFS this is indicated by the rotating symbol The DFS with arrow down empties the corresponding tank in the display 4 4 3 9 S...

Страница 11: ...easured value and enter it in the field Level 100 To get the values for 25 50 and 75 you must first divide the difference between the values 0 and 100 by 4 Add this value to the value at 0 this gives you the input value for 25 By further additions you get the values for 50 and 75 These values can be entered in the settings for 25 50 and 75 Method 3 You know the values for 0 25 50 75 and 100 Then e...

Страница 12: ... that new software has been detected and installed automatically During the update process the progress is displayed If the monitor starts normally after inserting the SD card no SD card has been detected or the software is up to date 8 Technical data Supply voltage DC 8 32 V Current consumption monitor Without tank sensor connected 83 mA at max display brightness 7 mA in sleep mode Measuring rang...

Отзывы: