background image

NO

.

Name

Def.

Valid 

Description

seconds per tick, default tick is 7 (70 
seconds).
0 means never send turn off light 
command.

8

Auto Report 

Battery Time

12

0 ~ 127

The interval time for auto report the 
battery level. 
0 means turn off auto report battery.
The default value is 12. The tick time can 
setting by the configuration No.11.

9

Auto Report 

LightSensor 

Time

12

0 ~ 127

The interval time for auto report the 
illumination. 
0 means turn off auto report illumination.
The default value is 12. The tick time can 
setting by the configuration No.11.

10

Auto Report 

Temperature

Time

12

0~ 127

The interval time for auto report the 
temperature. 
0 means turn off auto report temperature.
The default value is 12. The tick time can 
setting by the configuration No.11.

11

Auto Report 

Tick Interval

30

0 ~

0xFF

The interval time for auto report each tick.
Setting this configuration will effect 
configuration No.8, No.9 and No.10.
The unit is 1 minute.

12

Temperature

Differential 

Report

2

1~100 The temperature differential to report.

0 means turn off this function. 
The unit is 0.5 Fahrenheit.
Enable this function the device will detect 
per minutes. 
And when the temperature is over 140 

NO

.

Name

Def.

Valid 

Description

degree Fahrenheit, it will continue report.
Enable this functionality will cause some 
issue please see the detail in the 
“Temperature Report” section.

13

LightSensor 

Differential 

Report

20

1~100% The LightSensor Differential to report.

0 means turn off this function. 
The unit is percentage.
Enable this function the device will detect 
every percentage. 
And when the lightSensor is over 20 
percentage, it will continue report.

14

PIR Trigger 

Mode

1

1~3

PIR Trigger Mode

:

Mode1: Normal

Mode2: DayTime 

Mode3: AtNight 

15

PIR 

NightLine

2

1~

10000

PIR night line Lux conditions:

LightSensor determines whether 

the level is night. (Unit 1Lux)

Z-Wave Supported Command Class

Command Class 

Version 

Required Security Class 

Z-Wave Plus Info 

2

None 

Version 

3

Highest granted Security Class 

Manufacturer Specific 

2

Highest granted Security Class 

Security 2 

1

None 

8

Содержание PST07

Страница 1: ...oduct supports Over The Air OTA feature for the products firmware upgrade This product can be included and operated in any Z WaveTM network with other Z WaveTM certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 serie...

Страница 2: ...arking CE NCC Specifications are subject to change and improvement without notice Function Compare A B C D Model Description PST07 A Wall mount PST07 B Ceiling mount with Square shape PST07 C Ceiling mount with Round shape PST07 D Wall mount with lens cover Troubleshooting Symptom Cause of Failure Recommendation The device can not join to Z Wave network The device may in a Z Wave network Exclude t...

Страница 3: ...ocedure only in the event that the primary controller is lost or otherwise inoperable 1 Pressing button four times and keep about 5 seconds 2 IDs are excluded and all settings will reset to factory default SmartStart 1 Product has a DSK string you can key in first five digit to increment smart start process or you can scan QR code 2 SmartStart enabled products can be added into a Z Wave network by...

Страница 4: ...e Security 0x07 Event Tampering Product covering removed 0x03 Temperature Report When the PIR motion detected state changed the device will unsolicited to send the Sensor Multilevel Report to the nodes in the group 1 Sensor Type Temperature 0x01 Temperature differential report This function default is enabled to disable this function by setting the configuration NO 12 to 0 In the default when the ...

Страница 5: ...function When the device included with a security controller the device will auto switch to the security mode In the security mode the follow commands need using Security CC wrapped to communicate otherwise it will not response COMMAND_CLASS_VERSION_V3 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_C...

Страница 6: ...t let the device facing the window or the sunlight 3 Don t let the device facing the source of heat For instance the heater or the air condition Battery Installation When the device reports the low battery message users should replace the battery The battery type is CR123A 3 0V 6 ...

Страница 7: ...e the temperature report after event triggered 1 Disable 0 Enable 0 Bit6 Reserve NO Name Def Valid Description 0 Bit7 Reserve 5 Customer Function 3 All Customer function switch using bit control 1 Bit0 Tamper On Off 1 On 0 Off 1 Bit1 Red LED On Off 1 On 0 Off 0 Bit2 Motion Off 1 On 0 Off Note Depends on the Bit2 1 Report Notification CC Type 0x07 Event 0xFE 0 Bit3 Reserve 0 Bit4 Reserve 0 Bit5 Res...

Страница 8: ...s 1 minute 12 Temperature Differential Report 2 1 100 The temperature differential to report 0 means turn off this function The unit is 0 5 Fahrenheit Enable this function the device will detect per minutes And when the temperature is over 140 NO Name Def Valid Description degree Fahrenheit it will continue report Enable this functionality will cause some issue please see the detail in the Tempera...

Страница 9: ...urchased They can take this product for environmental safe recycling Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C http www philio tech com FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide rea...

Страница 10: ...unction with any other antenna or transmitter Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging you...

Отзывы: