in default. When it wake-up it will broadcast the “Wake Up Notifi-
cation” message to the network, and wake-up 10 seconds for re-
ceive the setting commands. The wake-up interval minimum set-
ting is 30 minutes, and maximum setting is 120 hours. And the in-
terval step is 30 minutes. If the user want to wake-up the device
immediately, please rotate to area A and pressing the touch but-
ton once. The device will wake-up for 10 seconds every single
time.
Configuration
* The configuration mark with star(*), means after the
remove the setting still keep, don't reset to factory
default. Unless the user execute the “RESET” procedure.
NO.
Name
Size
(Byte)
Def.
Valid
Values
Description
1
Basic Set
OFF level
1
0x00
0x00~0x63
Control the value represented
by the left-side in area D.
E.g. Setting this configuration
to 0x0F means range of
Command Basic Set value
start from 0x0F
2
Basic Set
ON level
1
0x63
0x00~0x63
Control the value represented
by the right-side in area D.
E.g. Setting this configuration
to 0x1E means range of
Command Basic Set value
start from 0x1E
10
Auto
Report
Battery
Time
1
12
1~127
The interval time for auto re-
porting the Battery level. 0
means turn off auto report
battery.
The default value is 12.
Bit 0
: Dimmer setting
method.
0 : Auto send Command Ba-
25
Customer
Function
1
0x00
0x00~0x03
sic Set after rotating.
1 : Send Command Basic Set
by touching key after rotating
Bit 1
: Disable buzzer in timer
mode.
0: Enable.
1: Disable.
Bit 2
: Disable timer mode.
0: Disable.
1: Enable.
Bit 3
: Disable buzzer in all
mode.
0: Enable.
1: Disable.
*26
Disable
Scene
Holding
report
1
0x00
0x00, 0x01
Send Central Scene Holding
when the button is held.
0x00: Enable.
0x01: Disable.
Installation
1. Fix the bracket on the wall.
2. There's a magnet on the backside of this device. It can stick to
the bracket.
Notice: Do not install the bracket on unstable wall, this may
cause miscarriage to control lights.
Firmware update over the air (OTA)
This device supports the Z-Wave firmware update via OTA. Let the
controller into the firmware update mode, and rotate to area A then
touch the button once to start update. After finish the firmware
download, the red LED will start to flash every 0.5 second. Please
don't remove the battery before the LED stop flashing.
Notice: recommend using OTA when the device is charging.