background image

Motion Sensor PSP05                                   

              PSP05-A                                        PSP05-B

              

PSP05-C                                        PSP05-D 

          

The  motion   sensor   PSP05  has   PIR  function,   based   on  Z-Wave

TM

technology.

This device is a Security Enabled Z-Wave Plus Product.  Z-Wave

TM

  is a

wireless   communication   protocol   designed   for   home   automation,

specifically   to   remotely   control   applications   in   residential   and   light

commercial environments. The technology uses a low-power RF radio

embedded or retrofitted into home electronics devices and systems,

such   as   lighting,   home   access   control,   entertainment   systems   and

household appliances.

This product can be included and operated in any Z-Wave

TM

  network

with other Z-Wave

TM

 certified devices from other manufacturers and/or

other applications.  All non-battery operated nodes within the network

will act as repeaters regardless of vendor to increase reliability of the

network. 

The device adopt the Z-Wave

TM

  500 series chip, when your Z-Wave

TM

network   system   is   all   made   by   Z-Wave

TM

  500   series   devices.   The

network system will have the advantages as below.

Concurrent multi-channel support reduces external interference.

Better RF range, improve about 10 meters in indoor.

Support 100 Kbps transmit speed, speed up communication.

Add to/Remove from Z-Wave

TM

 Network

There are two  keys in the device,  one is  tamper  key, another  is a

button.  Button  can add,  remove, reset or association from  Z-Wave

TM

network.

In the first time, add the device into the Z-Wave

TM

 network.  First, make

sure the primary controller is in the add mode. And then power on the 

device, just take out the insulation Mylar in the back side of the device.

The device will auto start the NWI (Network Wide Inclusion) mode. And

it should be included in 5 seconds. You will see the LED light ON one 

second.

1

Содержание PSP05

Страница 1: ...act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed sp...

Страница 2: ...is group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the button one time to abort the NWI mode Z WaveT...

Страница 3: ... the timing report except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flash about 5 seconds Please change another new battery PIR Warm Up When the device power on the PIR need to warm up before the operation The warm up time about 1 min...

Страница 4: ...gered the device will report the messages to the nodes in the group 1 The messages also include the battery level The user can switch the report by setting the configuration NO 7 bit6 battery When the event triggered the device will emit the signal to turn ON the lighting equipment those nodes are in the group 2 And delay a while to turn OFF the lighting equipment The delay time is setting by the ...

Страница 5: ...t is allowed any value but no effect Z Wave Supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLA...

Страница 6: ...oom 0 In the same room Default 1 In the different room Notice If this bit is 1 it is recommended also set the Bit1 to 1 cause the PIR triggered doesn t mean the people in that room NO Name Def Valid Description 0 Bit4 Disable delay 5 seconds to turn off the light when door window closed 1 Disable 0 Enable 0 Bit5 Disable auto turn off the light after door window opened to turn on the light 1 Disabl...

Страница 7: ...means never send turn off light command 10 Auto Report Battery Time 12 0 127 The interval time for auto report the battery level 0 means turn off auto report battery The default value is 12 The tick time can setting by the configuration No 20 20 Auto Report Tick Interval 30 128 127 The interval time for auto report each tick Setting this configuration will effect configuration No 10 NO Name Def Va...

Страница 8: ...ion which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced r...