Installation
1. To mount the device on the wall, you can choose using the tape, or
the screw.
2. Using the screw to fix the flood detector.
Warning:
1. Before the product is installed, please make sure the surface is clean.
Especially for the surface of glass and wood, keep it dry before
installation.
2. It is highly recommended to press the product on double-sided tape
for 30 seconds.
Z-Wave Configuration Settings
Notice:
*
All of the configuration, the data size is 1.
*
All of the configuration after the remove the setting still keep, don't
reset to factory default. Unless the user execute the “RESET”
procedure.
*
The reserve bit or not supported bit is allowed any value, but no
effect.
NO.
Name
Def. Valid
Description
1 Auto Report
Tick Interval
60
1 ~
0xFF
The interval time for auto report
each tick.(unit:minute)
2 Auto Report
Battery Time
6
1 ~
0xFF
The interval time for auto report the
battery level.
3 Customer
Function
13
All
Operation mode. Using bit to
control.
1
Bit0
: Disable auto report battery
function.
0 : Disable / 1 : Enable
0
Bit1
: Reserve.
1
Bit2
: Disable auto report flood
function.
0 : Disable / 1 : Enable
1
Bit3
: Turn off the beep sound.
0 : Disable the beep sound.
1 : Enable the beep sound.
0
Bit4
: Reverse flood signal.
1 : Reverse Mode, Short → Not
trigger, Open → Trigger.
0 : Normal Mode, Short → Trigger,
6