3. IDs are excluded and all settings will reset to 

factory default.

SmartStart

1. Product has a DSK string, you can key in first five 

digit to increment SmartStart process, or you can 

scan QR code.

Ex : mydsk

10209-46687-52248-13629-04783-07465-15776-56519

2. SmartStart enabled products can be added into a Z-

Wave network by scanning the Z-Wave QR Code 
present on the product providing SmartStart 
inclusion. No further action is required and the 
SmartStart product will be added automatically 
within 10 minutes of minutes On in the network 
vicinity.

notice1:The QR code can be found on the device 

PAT15 or on the box.

Association

This machine provides two groups of nodes. 

Group 1 can set 1 Nodes.

Group 2 can set 5 Nodes.

Group 1 is called Lifeline the device will report :

1.Notification report

2.Device Reset Locally Notification

3.Battery Report

4.Indicator Report

Group 2 is called Basic set the device will report :

1.Basic Set

Failed or success in add/remove the node ID can be viewed 

from Z-Wave

TM

 Controller.

Notice 1:

 Always RESET a Z-Wave

TM

 device before trying to add it to a

Z-Wave

TM

 network 

Z-Wave

TM

 Notification

After the device adding to the network, it will wake-up once per day in

default. When it wake-up it will broadcast the “Wake Up Notification”

message   to   the   network,   and   wake-up   10   seconds   for   receive   the

setting commands.

The wake-up interval minimum setting is 30 minutes, and maximum

setting is 120 hours. And the interval step is 30 minutes.

Press the tamper key once. The device will wake-up 10 seconds.

Z-Wave

TM

 Message Report

In default the device will using Notification Report to represent the

tamper trigger and flood trigger event.

* 

Flood Report: 

When the flood triggered, the device will unsolicited to send the report

to the nodes in the group 1.

Notification Report (V8)
Notification Type: Water Alarm (0x05)

Event: Water Leak detected,  Unknown Location (0x02)

4

Содержание PAT15

Страница 1: ... WaveTM 700 series chip when your Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Specification Rated 3VDC CR123A lithium battery Battery life 20 years RF dista...

Страница 2: ...ry message The user should replace the battery to new one The battery type is CR123A 3 0V The way to open the front cover please press the top position to release the cover Replace the new battery and install the cover back 1 Put the front cover bottom and press down 2 Push the front cover top 2 1 2 1 ...

Страница 3: ... power on the device just take out the insulation Mylar in the back side of the device The device will auto start the SmartStart Include mode Notice Including a node ID allocated by Z WaveTM Controller means Add or Inclusion Excluding a node ID allocated by Z WaveTM Controller means Remove or Exclusion Function Description Add 1 Have Z WaveTM Controller entered inclusion mode 2 Pressing the tamper...

Страница 4: ...eport 4 Indicator Report Group 2 is called Basic set the device will report 1 Basic Set Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Z WaveTM Notification After the device adding to the network it will wake up once per day in default When it wake up it will broadcast the Wake...

Страница 5: ... configuration NO 5 Notice The configuration NO 1 could change the tick interval the default value is 60 if setting to 1 that means the minimum auto report interval will be one minute Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will flash three times Please change another new...

Страница 6: ... to factory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no effect NO Name Def Valid Description 1 Auto Report Tick Interval 60 1 0xFF The interval time for auto report each tick unit minute 2 Auto Report Battery Time 6 1 0xFF The interval time for auto report the battery level 3 Customer Function 13 All Operation mode Using bit ...

Страница 7: ... Manufacturer Specific 2 Highest granted Security Class Multi Channel Association 3 Highest granted Security Class Powerlevel 1 Highest granted Security Class Version 3 Highest granted Security Class Configuration 4 Highest granted Security Class Notification 8 Highest granted Security Class Battery 1 Highest granted Security Class Disposal This marking indicates that this product should not be di...

Страница 8: ...res Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may n...

Отзывы: