background image

 

4. Firmware update over the air (OTA)

 

PAN35 is based on 700 series SoC and supports Firmware Update Command 

Class, it can receives the updated firmware image sent by controller via the Z-Wave 

RF media. It is a helpful and convenient way to improve some function if needed.

 

 

5.  Command Classes

 

The Switch supports Command Classes including…

 

Command Class

 

Version

 

Required Security Class

 

Z-Wave Plus Info

 

2

 

None

 

Security 0

 

1

 

None

 

Security 2

 

1

 

None

 

Supervision

 

1

 

None

 

Transport Service

 

2

 

None

 

Association

 

2

 

Highest granted Security Class

 

Association Group   

Information

 

3

 

Highest granted Security Class

 

Basic

 

2

 

Highest granted Security Class

 

Binary Switch

 

2

 

Highest granted Security Class

 

Configuration

 

4

 

Highest granted Security Class

 

Device Reset Locally

 

1

 

Highest granted Security Class

 

Firmware Update Meta Data

 

5

 

Highest granted Security Class

 

Indicator

 

3

 

Highest granted Security Class

 

Manufacturer Specific

 

2

 

Highest granted Security Class

 

Multi Channel Association

 

3

 

Highest granted Security Class

 

Multi Channel Command

 

4

 

Highest granted Security Class

 

Notification

 

8

 

Highest granted Security Class

 

Powerlevel

 

1

 

Highest granted Security Class

 

Version

 

3

 

Highest granted Security Class

 

 

Disposal   

 

This marking indicates that this product should not be disposed with 
other household wastes throughout the EU. To prevent possible harm to 
the environment or human health from uncontrolled waste disposal, 
recycle it responsibly to promote the sustainable reuse of material 
resources. To return your used device, please use the return and 
collection systems or contact the retailer where the product was 
purchased. They can take this product for environmental safe recycling.

 

Philio Technology Corporation

 

8F.,No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257,Taiwan(R.O.C)   

 

www.philio-tech.com

 

 

FCC Interference Statement

 

This equipment has been tested and found to comply with the limit’s for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 

protection against harmful interference in a residential installation. This equipment generates, 

uses and can radiate radio frequency energy and, if not installed and used in accordance with 

the instructions, may cause harmful interference to radio communications. However, there is 

no guarantee that interference will not occur in a particular installation. If this equipment does 

cause harmful interference to radio or television reception, which can be determined by turning 

the equipment off and on, the user is encouraged to try to correct the interference by one of the 

following measures:

 

• Reorient or relocate the receiving antenna.

 

• Increase the separation between the equipment and receiver.

 

• Connect the equipment into an outlet on a circuit different from that to which the receiver is 

Содержание PAN35

Страница 1: ...installing the unit in storming or raining weather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper install...

Страница 2: ...ed or check max load cannot exceed 85 C 230Vac 120Vac Resistive load Installation Steps 1 Connect PAN35 to AC N and L and COM connect to L 2 Connect Load1 and Load2 to NO1 and NO2 3 Connect external Switch to S1 and S2 Fig 1 Assembling For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Obs...

Страница 3: ...itch can be used for inclusion or exclusion for 3 minutes after power up Pressing Include button of PAN35 three times within 2 seconds will enter exclusion mode Node ID has been excluded 2s On 2s Off No node ID Reset Pressing Include button of PAN35 three times within 2 seconds will enter inclusion mode One press one flash Within 1 second press Include button of PAN35 again for 5 seconds IDs are e...

Страница 4: ... Report OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF 1 2 BASIC_SET SWITCH_BINARY_SET Since the switch has two relay both the load attached to the Switch will turn on or off upon receipt of the following commands from a Z Wave Controller Command Class Basic Basic Set Value 1 99 255 0xFF both the load atta...

Страница 5: ...when endpoint set to 1 PAN35 will reply ON 0xFF when Relay 1 is ON report OFF 0x00 when Relay 1 is OFF If endpoint set to 2 PAN35 will reply state of Relay2 Below is an example show a source endpoint 5 send a Get command to PAN35 endpoint 1 COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x05 this is the endpoint of command owner here we assume endpoint is 5 if the owner doesn...

Страница 6: ...ge Toggle mode 2 Restore switch state mode 1 0 2 1 0 Switch off 1 Last switch state 2 Switch on 3 1 External switch mode Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge Toggle mode default value is Edge mode Edge mode this mode is suitable for the bi stable wall switch that has indicator point on the switch and the same position correspond to same state of relay1 and relay2 if t...

Страница 7: ...hout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation...

Страница 8: ...erference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter 警語 警語 警語 警語 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更 頻率 加大功率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全...

Отзывы: