2
Troubleshooting
Symptom
Cause of Failure
Recommendation
The Switch not working and
LED off
1.
The Switch is not connect
to the Main power
2.
The Switch break down
1.
Check power connections
2. Don’t open up the Switch and send
it for repair.
The Switch LED
illuminating, but cannot
control the ON/OFF
Switch of the load attached
Check if the load connect
into the Switch has its own
ON/OFF switch
Set the ON/OFF switch of the load
attached to ON
The Switch led illuminating,
but the Detector cannot
control the Switch
1. Not carry out association
2. Same frequency
interference
1. Carry out association
2. Wait for a while to re-try
LED keep flashing
continuously, but cannot
control
Overload occurs
Remove the load attached or check
max. load cannot exceed 85°C
(230Vac/120Vac) (Resistive load)
Installation Steps
1. Connect PAN35 to AC N and L and COM connect to L.
2. Connect Load1 and Load2 to NO1 and NO2.
3. Connect external Switch to S1 and S2.
Fig 1. Assembling
For Instruction to http:// www.philio-tech.com
DANGER
Danger of electrocution!
All works on the device may be performed only by a qualified and licensed
electrician. Observe national regulations.
Any works introducing changes into the configuration must be always
performed with disconnected voltage.
Choosing a Suitable Location
1. Do not locate the Module facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Module is 0°C~40°C.
3. Do not locate the Module where exists combustible substances or any source
of heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of Module will become a little bit hot of which
phenomenon is normal.