2. The switch is protected 

The Switch LED 
illuminating, but the 
Detector cannot control 
the Switch 

1. Not carry out 

association 

2. Same frequency 

interference 

1. Carry out association 
2. Wait for a while to re-try

 

LED keep flashing, but 
cannot control 

Overload occurs 

Remove the load attached or check max. 
load cannot exceed 13.0A

 

 

Specification 
 

Operating Voltage 

100~120Vac/ 60Hz; 220~240Vac/ 50Hz

 

Maximum Load

 

13A (

Resistive Load)

 

Range 

Minimum 40 m in door 100m outdoor line of sight

 

Operating Temperature  0°C ~ 40°C

 

Frequency Range 

908.4MHz & 916.0MHz/ USA (PAN15-1);   
922~927MHz/ Taiwan/ Japan (PAN15-2)

 

** Specifications are subject to change and improvement without notice.                           

 

FCC ID : RHHPAN15

 

 

 

 

 

Warning: 

1.Plug out to disconnect from power supply; Do not plug in line.

 

 

2. Do not exceed the max rating

 

Disposal   

 

This marking indicates that this product should not be disposed with 
other household wastes throughout the EU. To prevent possible harm to 
the environment or human health from uncontrolled waste disposal, 
recycle it responsibly to promote the sustainable reuse of material 
resources. To return your used device, please use the return and 
collection systems or contact the retailer where the product was 
purchased. They can take this product for environmental safe recycling

 

 

Company of License Holder

Philio Technology Corporation 

Address of License Holder

8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New 

Taipei City 24257, Taiwan(R.O.C)

    

FCC Interference Statement

FCC Interference Statement

FCC Interference Statement

FCC Interference Statement

 

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules.   

These limits are designed to provide reasonable protection against harmful interference in a 

residential installation.   

This equipment generates, uses and can radiate radio frequency energy and, if not installed and 

used in accordance with the instructions, may cause harmful interference to radio 

communications.   

However, there is no guarantee that interference will not occur in a particular installation.   

If this equipment does cause harmful interference to radio or television reception, which 

can be determined by turning the equipment off and on, the user is encouraged to try to correct 

the interference by one of the following measures:

 

• 

Reorient or relocate the receiving antenna.

 

• 

Increase the separation between the equipment and receiver.

 

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

 

• 

Consult the dealer or an experienced radio/TV technician for help. 

This device complies with Part 15 of the FCC Rules. Operation is subject 

to the following two conditions: 

(1) This device may not cause harmful interference, and 

(2) This device must accept any interference received, including interference that may cause 

undesired operation. 

FCC Caution: Any changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate this equipment. 

This transmitter must not be co-located or operating in conjunction with any other antenna or 

transmitter.

 

Содержание PAN15-2

Страница 1: ... switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a wall o...

Страница 2: ...d intervals Overload When overload state occurs the Switch is disabled of which LED flashes on and off alternately at 0 2 second intervals Overload state can be cleared by unplugging and reconnecting the Switch to the wall outlet Choosing a Suitable Location 1 Do not locate the Switch facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do not...

Страница 3: ...uping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consumption of load vary over 5 it will send Meter report to the nodes of Grouping 1 Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Pr...

Страница 4: ... Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 4 Size 2 Meter Value V Example Scale 0x04 V Precision 1 Size 2 Bytes V Meter Value 1 0x09 V Meter Value 2 ...

Страница 5: ...p1 node The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr 3 2 KWH Meter Report Period If the setting is configured for 1hour set value 6 the PAN15 will report its Accumulated Power Consumption KW h every 1 hour to Group1 node The maximum interval to report its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days 3 3 Threshold of c...

Страница 6: ...uence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update over the air OTA PAN15 is based on 500 series SoC and supports Firmware Update Command Class it can receives the updated firmware image sent by controller via th...

Страница 7: ...erence Statement FCC Interference Statement FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if no...

Страница 8: ...8 ...