4
Example:
Scale = 0x02 (W)
Precision = 1
Size = 4 Bytes (W)
Meter Value 1 = 0x00 (W)
Meter Value 2 = 0x00 (W)
Meter Value 3 = 0x03 (W)
Meter Value 4 = 0xEA (W)
Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W
2-2-2 Accumulated Power Consumption (KW/h)
When receiving Meter Get Command, it will report Meter Report Command to
the node.
Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 KW/h)]
Meter Report Command: [Command Class Meter
,
,
,
,
Meter Report
,
,
,
,
Rate Type =
0x01
,
,
,
,
Meter Type = 0x01
,
,
,
,
Precision = 2
,
,
,
,
Scale = 0
,
,
,
,
Size = 4
,
,
,
,
Meter Value(KWh)]
Example:
Scale = 0x00 (KWh)
Precision = 2
Size = 4 Bytes (KW/h)
Meter Value 1 = 0x00(KWh)
Meter Value 2 = 0x01(KWh)
Meter Value 3 = 0x38(KWh)
Meter Value 4 = 0xA3(KWh)
Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter
Value 3*256) + (Meter Value 4) = 800.35 (KW/h)
2-2-3 Clearing accumulated power consumption
Meter Reset Command: [Command Class Meter, Meter Reset]
2-2-4 AC load Voltage (V)
When receiving Meter Get Command, it will report Meter Report Command to the
node.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)]
Meter Report Command:
[Command Class Meter
,
,
,
,
Meter Report
,
,
,
,
Rate Type = 0x01
,
,
,
,
Meter Type = 0x01
,
,
,
,
Precision = 1
,
,
,
,
Scale = 4
,
,
,
,
Size = 2
,
,
,
,
Meter Value(V)]
Example:
Scale = 0x04 (V)
Precision = 1
Size = 2 Bytes (V)
Meter Value 1 = 0x09(V)
Meter Value 2 = 0x01(V)
AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)
2-2-5 AC load current (
I
)
When receiving Meter Get Command, it will report Meter Report Command to the
node.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)]
Meter Report Command:
[Command Class Meter
,
,
,
,
Meter Report
,
,
,
,
Rate Type = 0x01
,
,
,
,
Meter Type = 0x01
,
,
,
,
Precision = 2
,
,
,
,
Scale = 5
,
,
,
,
Size = 2
,
,
,
,
Meter Value(
IIII
)]
Example:
Scale = 0x05 (
I
)
Precision = 2
Size = 2 Bytes (
I
)
Meter Value 1 = 0x01(
I
)
Meter Value 2 = 0x21(
I
)
AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)
2-2-6 load power factor (PF)
When receiving Meter Get Command, it will report Meter Report Command to the
node.