N
O.
Name
Def
.
Valid
Description
some issue please see the detail in
the “Temperature Report” section.
19
LightSensor
Differential
Report
10 1~100%
The LightSensor Differential to
report.
0 means turn off this function.
The unit is percentage.
Enable this function the device will
detect every percentage.
And when the lightSensor is over
10 percentage, it will continue
report.
20
Temperature
Threshold
line 1
20
- 20 ~
50C
Temperature difference return:
The default is 20 degrees C.
21
Temperature
Threshold
line 2
25
- 20 ~
50C
Temperature difference return:
The default is 25 degrees C.
22
Temperature
Threshold
line 3
30
- 20 ~
50C
Temperature difference return:
The default is 30 degrees C.
23
Temperature
Threshold
line 4
35
- 20 ~
50C
Temperature difference return:
The default is 35 degrees C.
24
Temperature
Threshold
line 5
40
- 20 ~
50C
Temperature difference return:
The default is 40 degrees C.
25 PIR Trigger
Mode
1
1~3
PIR Trigger Mode:
Mode1: Normal
Mode2: DayTime
N
O.
Name
Def
.
Valid
Description
Mode3: AtNight
26
PIR
NightLine
1
1~100
PIR night line Lux conditions:
LightSensor determines whether
the level is night. (Unit 100Lux)
Z-Wave Supported Command Class
Command Class
Version
Required Security Class
Z-Wave Plus Info
2
None
Version
3
Highest granted Security Class
Manufacturer Specific
2
Highest granted Security Class
Security 2
1
None
Device Reset Locally
1
Highest granted Security Class
Association
2
Highest granted Security Class
Association
Group
Information
1
Highest granted Security Class
Powerlevel
1
Highest granted Security Class
Basic
1
Highest granted Security Class
Configuration
1
Highest granted Security Class
Notification
8
Highest granted Security Class
Firmware Update Meta
Data
4
Highest granted Security Class
Supervision
1
None
9