![Philio Technology Corporation PSM11 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/philio-technology-corporation/psm11/psm11_manual_1537990005.webp)
*
Wake
When the device power on, the device will wake about 20 seconds. In
this duration, the controller can communicate with the device. Normally
the device is always sleeping to save the battery energy.
Over The Air (OTA) Firmware Update
The device support the Z-Wave firmware update via OTA.
Let the controller into the firmware update mode, and then press the
tamper key once to start the update.
After finish the firmware download,
please don't remove the
battery
, otherwise it will cause the firmware broken, and the device
will no function.
After the LED stop flash, it is recommended that the user power up the
device.
Caution
: After remove the battery, please wait about 30
seconds, and then re-install the battery.
Battery Installation
When the device reports the low battery message, users should replace
the battery. The battery type is CR123A, 3.0V.
Installation
. In the first time, add the device into the Z-Wave
TM
network. First,
make sure the primary controller is in the inclusion mode. And then
power on the device, just take out the insulation Mylar in the back side
of the device. The device will auto start the SmartStart Include mode.
You will see the LED light ON one second. (refer to fig. 1)
2. Let the controller associate with the device into the first group, any
light switch that intend to be turned on when the device trig please
associate with the device into the second group.
3. In the accessory pack, There is double-coated tape. you can use a
double-coated type for the test at the beginning. The right way for
double coated type installation is to stick it to the position of the back.
the sensor will enter the test mode, You may test if the installed
position is good or not by this way (refer to fig. 2 and fig. 3)
5