Philio Technology Corporation PSM11 Скачать руководство пользователя страница 4

Notice 1:

 Always RESET a Z-Wave

TM

 device before trying to add it to a

Z-Wave

TM

 network 

Z-Wave

TM

 Notification

After the device adding to the network, it will wake-up once per day in

default. When it wake-up it will broadcast the “Wake Up Notification”

message   to   the   network,   and   wake-up   10   seconds   for   receive   the

setting commands.

The wake-up interval minimum setting is 30 minutes, and maximum

setting is 120 hours. And the interval step is 30 minutes.

Press the tamper key once. The device will wake-up 10 seconds.

Z-Wave

TM

 Message Report

In default the device will using Notification Report to represent the

tamper trigger and door / window trigger event.

* 

Door / Window Report: 

When the door/window state changed, the device will unsolicited to

send the report to the nodes in the group 1.

Notification Report (V8)
Notification Type: Access Control (0x06)

Event: Door/Window is open (0x16)

          Door/Window is closed (0x17)

* 

Tamper Report: 

The tamper key pressed over 5 seconds. The device will into the alarm

state.   In   that   state,   if   the   tamper   key   be   released,   the   device   will

unsolicited to send the report to the nodes in the group 1.

Notification Report (V8)
Notification Type: Home Security (0x07)

Event: Tampering. Product covering removed (0x03)

* 

Timing Report:

Beside   the   event   triggered   could   report   message,   the   device   also

support the timing unsolicited report of the status.

Battery level report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 1.

Low battery report: When the battery level is too low, every 30

minutes will report once.

Door/window state report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 5.

Notice  

: The configuration NO. 1 could change the tick interval, the

default value is 60, if setting to 1, that means the minimum auto report

interval will be one minute. 

Power Up Procedure

* 

Battery Power Check

When the device power up, the device will detect the power level of the

battery immediately. If the power level is too low, the LED will flash

three times. Please change another new battery.

4

Содержание PSM11

Страница 1: ...r Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Specification Power 3VDC CR123A lithium battery Battery life 20 years RF distance Min 40M indoor 100M outdoor ...

Страница 2: ...hot oven or mechanically crushing or cutting of a battery that can result in an explosion leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas a battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas The marking information is located at...

Страница 3: ...amper key four times within 1 5 seconds and do not release the tamper key in the 4th pressed and the LED will light ON 2 After 3 seconds the LED will turn OFF after that within 2 seconds release the tamper key If successful the LED will light ON one second Otherwise the LED will flash once 3 IDs are excluded and all settings will reset to factory default SmartStart 1 Product has a DSK string you c...

Страница 4: ...y pressed over 5 seconds The device will into the alarm state In that state if the tamper key be released the device will unsolicited to send the report to the nodes in the group 1 Notification Report V8 Notification Type Home Security 0x07 Event Tampering Product covering removed 0x03 Timing Report Beside the event triggered could report message the device also support the timing unsolicited repo...

Страница 5: ... low battery message users should replace the battery The battery type is CR123A 3 0V Installation In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the SmartStart Include mode You will see the LED light O...

Страница 6: ...ion 1 Auto Report Tick Interval 60 1 0xFF The interval time for auto report each tick unit minute 2 Auto Report Battery Time 6 1 0xFF The interval time for auto report the battery level 3 Customer Function 3 All Operation mode Using bit to control 1 Bit0 Disable auto report battery function 0 Disable 1 Enable 1 Bit1 Disable auto report door window function 0 Disable 1 Enable 0 Bit2 Reserve 0 Bit3 ...

Страница 7: ...ity Class Configuration 4 Highest granted Security Class Notification 8 Highest granted Security Class Battery 1 Highest granted Security Class Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustai...

Страница 8: ...let on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including inter ference that may cause undesired oper...

Отзывы: