![Philio Technology Corporation PSM11 Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/philio-technology-corporation/psm11/psm11_manual_1537990004.webp)
Notice 1:
Always RESET a Z-Wave
TM
device before trying to add it to a
Z-Wave
TM
network
Z-Wave
TM
Notification
After the device adding to the network, it will wake-up once per day in
default. When it wake-up it will broadcast the “Wake Up Notification”
message to the network, and wake-up 10 seconds for receive the
setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum
setting is 120 hours. And the interval step is 30 minutes.
Press the tamper key once. The device will wake-up 10 seconds.
Z-Wave
TM
Message Report
In default the device will using Notification Report to represent the
tamper trigger and door / window trigger event.
*
Door / Window Report:
When the door/window state changed, the device will unsolicited to
send the report to the nodes in the group 1.
Notification Report (V8)
Notification Type: Access Control (0x06)
Event: Door/Window is open (0x16)
Door/Window is closed (0x17)
*
Tamper Report:
The tamper key pressed over 5 seconds. The device will into the alarm
state. In that state, if the tamper key be released, the device will
unsolicited to send the report to the nodes in the group 1.
Notification Report (V8)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
*
Timing Report:
Beside the event triggered could report message, the device also
support the timing unsolicited report of the status.
•
Battery level report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 1.
•
Low battery report: When the battery level is too low, every 30
minutes will report once.
•
Door/window state report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 5.
Notice
: The configuration NO. 1 could change the tick interval, the
default value is 60, if setting to 1, that means the minimum auto report
interval will be one minute.
Power Up Procedure
*
Battery Power Check
When the device power up, the device will detect the power level of the
battery immediately. If the power level is too low, the LED will flash
three times. Please change another new battery.
4