Charcoal filter (filter version only)
It absorbs unpleasant odours caused by cooking.
The saturation of the charcoal filter occurs after more or less prolonged use, depending on the type of cooking
and the regularity of cleaning of the grease filter. In any case it is necessary to replace the cartridge at least
every four mounths (or when the filter saturation indication system – if envisaged on the model in possession –
indicates this necessity).The charcoal filter may NOT be washed or regenerated.
Replacing lamps
Disconnect the appliance from the electricity.
Warning!
Prior to touching the light bulbs ensure they are cooled down.
Replace the old light bulb with the one of the same type as specified in the feature label or near the light lamp
on the hood.
1.
Using a flat head screwdriver or equivalent tool, carefully pry loose the light cover.
2.
Remove the damaged light and replace with a new 12 Volt, 20 Watt (Maximum) halogen light made for a
G-4 base SUITABLE FOR USE IN OPEN LUMINAIRES. Follow package directions and do not touch new
light with bare hands.
3.
Reinstall the light cover. (it will snap shut).
If the lights do not work, make sure that the lamps are fitted properly into their housings before you call for