Never cover the ventilation grill. Pull out the power plug by pulling on the plug itself, never pull on the cord 
when disconnecting the appliance.

    Before turning on the appliance allow it to stand in its fi nal location for 12 hours, the coolant circuit 

will stabilise in this way and no operating problems will occur. Before connecting the appliance to the 
power grid check that it is perfectly dry inside – especially in the corners.

Danger warning
The coolant may be highly fl ammable, depending on its composition. The coolant circuit was 
hermetically closed and sealed and was tested many times for possible leaks. Any unqualifi ed 
tampering with the product may cause a fi re hazard. Check that there is no mechanical interruption 
or eff ect on the coolant circulation, namely in the accessible parts around the compressor.
Only professionally qualifi ed persons may work on the cooling system.

CLEANING BEFORE USE

Check that you have removed from the appliance all adhesive tape used to hold accessories . Then clean all the 
inside parts using lukewarm water with a neutral cleaning agent, vinegar or sodium carbonate – in this way 
you will remove the characteristic odour of new parts – then dry carefully. Do not use detergents or aggressive 
agents, which could damage the surfaces.

ELECTRICAL CONNECTION

Before connecting the power plug to the power socket, check that:



Your hands are completely dry.



The voltage and frequency shown on the rating label of the appliance corresponds to that in the home 
power grid (permitted tolerance from -6% to +6% for nominal voltage. For use with diff erent voltages, use 
a voltage changer with the corresponding parameters).



The cord and the plug are not damaged or caught under heavy objects.



The power cord is not excessively tensioned, it is not permitted to use an extension cord.

    Do not connect the appliance to a voltage rectifi er (e.g. solar power plant) or use an extension cord.

  The appliance must be connected to a working grounding lead. 

 

 If the power socket of the home system is not grounded in accordance with the current legal regulations, 
connect the appliance after consulting a specialised technician to the grounding lead itself.

 

 The manufacturer takes no responsibility for injuries caused as a result of not following these 
instructions.

    If you do not correctly level the refrigerator during the installation, the door may not close shut and 

seal properly, which may cause problems with the cooling, or moisture. Levelling the refrigerator 
is very important.

Level the refrigerator using the adjustable feet – turn them clockwise to lift the refrigerator and turn them 
anticlockwise to lower the refrigerator.

CHANGING THE DOOR OPENING DIRECTION

If you need to change the door opening direction, contact an authorised service centre.

Содержание PTL 1211 BI

Страница 1: ...REFRIGERATOR USER S MANUAL PTL 1211 BI...

Страница 2: ...Dear customer Thank you for buying a PHILCO brand product So that your appliance serves you well please read all the instructions in this user s manual...

Страница 3: ...king 6 Placement 7 Cleaning before use 8 Electrical connection 8 Changing the door opening direction 8 PART 4 SETTING THE TEMPERATURE 9 PART 5 INTERNAL LIGHTING 9 PART 6 ARRANGEMENT OF FOOD 10 Advice...

Страница 4: ...ns in the relevant chapter When installing the appliance in its place or when moving the appliance the power cord could be penetrated or damaged Check that the power cord is not interfering anywhere B...

Страница 5: ...toy for children For appliances with door locks do not leave keys within the reach of children If you will no longer be using the refrigerator remove the door seals and store it in a safe place In thi...

Страница 6: ...ly prevent contact with an open flame and hot surfaces Because the R600a gas is heavier than air it may become very concentrated at the level of the ground where ventilation is weak First aid Inhalati...

Страница 7: ...nt cover 8 Cheese and butter shelf 3 Fruit and vegetable compartment 9 Cheese and butter shelf cover 4 Feet for levelling the appliance 10 Light switch 5 Bottle shelf 11 Thermostat 6 Middle shelf NOTE...

Страница 8: ...ystyrene parts etc must be kept out of the reach of children because they present a possible source of danger Carefully inspect the appliance If you discover any defects stop the installation and cont...

Страница 9: ...s have been damaged during the installation Use the appliance only for the purposes for which it has been designed The appliance must be located on a rigid and even surface In this way you will ensure...

Страница 10: ...aces ELECTRICAL CONNECTION Before connecting the power plug to the power socket check that Your hands are completely dry The voltage and frequency shown on the rating label of the appliance correspond...

Страница 11: ...f the micro organisms These process are slowed down by a declining temperature For this reason we recommend the middle settings of the temperature control knob NOTE To achieve the desired temperature...

Страница 12: ...ly and safely closed Advice about refrigerating food While the air in the refrigerator circulates areas with various temperatures arise These areas are especially useful for storing various types of f...

Страница 13: ...ecommend a general purpose detergent with a neutral pH The use of steam cleaning appliances is extremely dangerous and so is strictly forbidden Wipe the inside area and the accessories with clean wate...

Страница 14: ...ons condensate may form on the exterior walls of the appliance This does not indicate a malfunction and this condensate will disappear as soon as the temperature rises Contact the service department o...

Страница 15: ...heet of paper on all sides Call an authorised service centre if it is possible to pull out the paper without resistance at one or more points Is the appliance exposed to direct sunlight or is it locat...

Страница 16: ...de of the inside wall or on the rear side of the appliance Technical specifications Model PTL 1211 BI Climatic class N Net volume 204 l Operating voltage 220 240 V 50 Hz Maximum power 146 W Power cons...

Страница 17: ...s and help in preventing the potential negative impact on the environment and human health which could be caused as a result of improper liquidation of waste Please ask your local authorities or the n...

Страница 18: ......

Отзывы: