Temperature Setting
To set the required heating tem-
perature and to maintain a fixed air
temperature in the room, turn on
the device and turn the thermostat
adjustment knob to the right up to
the maximum value. When the tem-
perature in the room is comfortable
for you, start to turn the thermostat
adjustment knob slowly to the left
until you hear a click. Thus the device
will memorize the temperature which
is comfortable for you and it will
maintain this temperature by turning
on and off automatically.
The difference between On/Off
temperature for defined area
can range from 0.1 to 3 degrees
depending on volume and ther-
mal insulation of area. When the
device is used in large rooms
susceptible to fast cooling we
recommend to set the temper-
ature at 2-3 degrees above the
desired level for efficient opera-
tion of the heater.
Overheating Protection Function
Device is provided with a circuit
breaker that is triggered when
the maximum temperature limit is
reached. In case of overheating the
device turns off automatically.
Installation of Device
Recommended Installation
The convector shall be installed so
that produced heat will mix maxi-
mum volume of air. The convector
should be attached in accordance
with applicable requirements. The
switch and other mechanisms
should be away from a person
who takes bath or shower. The
device should not be exposed to
water splashes. If the device is
covered there is a risk of over-
heating. It is strictly forbidden to
cover or plug inlets and outlets (air
grids) as it can cause an accident
or damage the device. Do not
place the convector behind cur-
tains, doors, under wall opening
or ventilation hole. Keep minimum
distance required for installation
on floor, surface, near furniture,
etc. (Figure 3).
Dimensions in mm
100 min.
100 min.
100 min.
100 min.
Figure 3
Floor Mounting:
• Remove the wall bracket from the
convector as follows:
Содержание PCH/AG-1000 MF
Страница 1: ...PCH AG MF...
Страница 2: ...2 PHILCO PCH AG MF PHILCO PHILCO 3 3 4 5 8 8 9 9 9 WWW SERVICEWORLD GR 210 6203838...
Страница 3: ...3 1 2 3 4 5 1 1 2 3 4 5 1 O a b c 2 1 3 2 4 2 1 2 LED 3 4 5...
Страница 4: ...4 PHILCO LED I Air Gate Air Gate NANO Additional filters Antistatic dust filter...
Страница 5: ...5 3 6 0 1 3 2 3...
Страница 6: ...6 PHILCO 3 Dimensions in mm 100 min 100 min 100 min 100 min 3 4 fasteners 4 5 6 6 5 6 6...
Страница 7: ...7 flexible braces a b c 5 6 7 8 7 8 L N LO HI N1 HI LO COM L1 I II KSD 9 L N...
Страница 9: ...9 www service world gr 4 25 30 40 90 20 80 C 40 90...
Страница 10: ...10 PHILCO 17 145 10...
Страница 19: ...19...