4
Installation (continued):
Installation Note:
Secure the filter (Input assem-
bly) to an inter-cell connector.
Insert the barb fitting of male
quick connect fitting into the
tubing.
Slide the twist lock ring onto
the free end of the Water Input
Assembly.
Push twist-lock ring and quick
connect together & twist to lock
onto the tubing.
The standard Stealth Valve may not fit into
Exide Technologies/GNB flat-plate Batteries
or Crown MaxHaul because of the internal
construction of these cells. For either of
these batteries use the Stealth Slim.
Due to the reduced shut off force of the
narrow float Stealth Slim is not
recommended for use in battery with wider
openings. Use standard Stealth Watering
System whenever possible.
Stealth
Slim Valve
Standard
Stealth Valve