FAQ and Troubleshooting

Can  I  use  this  device  with  equipment  that  is  not 

PoE ready?

No, this device will not act as a splitter to divide the 

data over Ethernet and power via a DC cable. There 

is a list of available splitters available on the website 

www.berger-stromversorgungen.de  This unit may act as 

a data switch to relay data only over 100 meters.

Can I connect multiple devices to extend my reach 

beyond 200 meters?

Yes  it  is  possible  to  add  more  than  one  device  to 

extend the reach of PoE; however only one can be 

a  POE61S-4AF  and  it  must  be  connected  directly 

into the Ultra or Mega PoE midspan power injector. 

To extend the connection an additional 100m to 300 

or  more,  then  Phihong  recommends  the  POE16S-

1AFG  extender  which  will  be  available  in  the  fi rst 

half of 2010. Since the POE60S-4AF has an internal 

signature  resistance  at  12.5K  and  its  output  must 

detect  25K  signature  resistance,  the  device  will 

not  work  if  connected  to  another  POE61S-4AF  or 

POE60S-4AF.

  

If  your  question  is  not  listed  here  and  need  further  information 

please contact Phihong Sales. For a full listing of available contact 

information  please  visit  the  Contact  Us  section  of  the  Berger 
Stromversorgungen website www.berger-stromversorgungen.de 

Features

Input

Phihong Ultra (75W) 

or Mega PoE (95W) 

or optional DC Power 

Adapter

Output

4 Ports at 15.4W max. 

per port; IEEE802.3af 

compatible

Ease of Installation

DHCP Detection

Safety Approval

CE Certifi ed

Troubleshooting

Detection:

Once a compliant load is attached to the input and 

output RJ45 connectors, the Green LED for POWER 

IN  will  illuminate  as  well  as  the  POWER  OUT  LED 

for each connected port indicating that the power is 

connected. If data is being transferred then a yellow 

LED will blink for DATA IN and under each connected 

port.  A  100M  Data  Rate  and  Full  Duplex  will  yield 

Green  LEDS  for  DATA  in  and  DATA  OUT  for  each 

connected  port.  The  LEDs  will  not  illuminate  if  Half 

Duplex or 10M Data Rate. Should the load be non-

complaint all LEDs will remain off.