MOUNT THE PUSH PLATES OR OTHER ACTUATORS
MINIMUM INSTALLATION REQUIREMENTS
The type of actuator that you are installing will determine the installation
procedures. See the manufacturer’s instructions that came with the product.
Make sure to follow the ANSI/BHMA A156.19 requirements regarding the
placement of actuators:
ANSI/BHMA A156.19 requires that the actuator switch:
•
“...be activated by a knowing act.” See the glossary of terms for a complete
definition, but in summary, the operator must be activated consciously. It must
not open without the person’s initiating.
•
be located within one to five feet from the door, but never more than 12 feet.
•
must remain accessible from the swing side when the door is open.
•
not to be located in a position where the user would be in the path of the
moving door.
•
be mounted so the user is in full sight of the door when activating the switch.
•
have an installation height of a minimum of 34 in. (864 mm) and a maximum of
48in. (1219 mm).
Содержание D-4990
Страница 1: ...Precision D 4990 Low Energy Door Operator Product Overview...
Страница 6: ...DOOR FORCE GAUGE...
Страница 7: ...DOOR FORCE GAUGE...
Страница 13: ...FULL CYCLE LOW ENERGY POWER OPEN DOOR 0 90 Consult ANSI BHMA A156 19 2007 for exact wording and specifications...
Страница 25: ...PRIMARY APPLICATIONS Approximately 90 of low energy door operators are installed on outward swinging doors...
Страница 26: ...PRIMARY APPLICATIONS...
Страница 27: ...MINIMUM INSTALLATION REQUIREMENTS...
Страница 34: ...CONTROLLER PLUG IN CONNECTORS D 4990 CONTROLLER...
Страница 48: ...Adjustment Valves Adjustment Valves...
Страница 49: ...SAMPLE ACTIVATION DEVICES...
Страница 65: ......