OPENING TIMES – LOW ENERGY POWER OPEN DOOR
0º
90º
60º
1 second to full open
1.5 seconds to full open
2 seconds to full open
Back-check at 80 degrees
Back-check at 70 degrees
Back-check at 60 degrees
Time From Backcheck (Open check) to Full-Open Position (TABLE
II
)
60º BACKCHECK position to Full-Open = 2 sec.
Minimum opening time from
Backcheck to full-open is 1 - 2
seconds, depending on degree of
backcheck (refer to Table
II
)