SPECIFICATIONS 

Rated Heat Input (Propane)

Propane Regulator Pressure

Clearance to combustible surfaces

41,000 BTU/hr

11 inches water column

Sides: 3 feet (36 in.), Top: 5 feet (60 in.)

WARNING: 

This product can expose you to chemicals 

including chromium (hexavalent compounds) AND BENZENE, 
which are known to the State of California to cause cancer 
and birth defects or other reproductive harm. 
For more information go to:
www.P65warnings.ca.gov/furniture.  

Standard 20 Ib.tank

Figure 1

The propane gas supply cylinder to be used must be constructed and marked in accordance with the U.S. Department of 
Transportation (D.O.T.) Specifications for propane Gas Cylinders, or the Standard for Cylinders, Spheres and Tubes for 
Transportation of Dangerous Goods and Commission, CAN/CSA-B339, as applicable.

The propane gas supply cylinder to be used must have a listed overfilling prevention device (See Figure 1).

The propane gas supply cylinder to be used must have a cylinder connection device compatible with the connection for the 
appliance.
A self-contained propane gas cylinder for use with this appliance must have a capacity of 20 Ibs cylinder (Height approximately 
18 in., Tank Body approximately 12 in. diameter, Base approximately 8 in. diameter).

The cylinder supply system must be arranged for vapor withdrawl.

The cylinder used must include a collar to protect the cylinder valve.

This appliance shall be used only outdoors in a well-ventilated space and shall not be used in a building, garage or any other 
enclosed space.

When this appliance is not in use, the gas must be turned off at the supply cylinder.

Storage of this appliance indoors is permissible only if the cylinder is disconnected and removed from the appliance.

Cylinders must be stored outdoors in a well-ventilated area out of the reach of children. Disconnected cylinders must have 
threaded valve plugs tightly installed and must not be stored in a building, garage or any other enclosed areas.

Do not store a spare propane gas cylinder under or near this appliance;

Never fill the cylinder beyond 80% full; 

Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder 
valve that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.

IMPORTANT SAFETY INFORMATION (About Propane Gas)

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

4

LIFE GETS BETTER WITH PHI VILLA

Содержание E02GS021

Страница 1: ...ing to the store please contact our Customer Service service alphamarts com We appreciate the trust and confidence you have placed in PHI VILLA through the purchase of our product We strive to continu...

Страница 2: ...Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or serv...

Страница 3: ...equent cleaning may be required as necessary It is imperative that the control compartment burners and circulating air passageways of the appliance are kept clean CAUTION The propane gas pressure regu...

Страница 4: ...ty of 20 Ibs cylinder Height approximately 18 in Tank Body approximately 12 in diameter Base approximately 8 in diameter The cylinder supply system must be arranged for vapor withdrawl The cylinder us...

Страница 5: ...E Narrow glass Base 1 F Door 1 G Weather cover 4 4 2 2 24 H Foot glider PRE ASSEMBLED Bolt M6 x 5 mm Caster with locking device Ground fixer Caster HARDWARE CONTENTS AA Bolt M6 x 5 mm X24 X2 Caster C...

Страница 6: ...en any mechanical or propane fueled equipment is involved These precautions are necessary when using storing and servicing Using this equipment with the respect and caution demanded will reduce the po...

Страница 7: ...opane vapors are heavier than air and can accumulate in low places If you smell gas leave the area immediately Never install or remove propane cylinder while heater is lighted near flame other ignitio...

Страница 8: ...set up for vapor withdrawal Store or use propane gas in compliance with local ordinances and codes or with ANS NFPA 58 Turn off propane when not in use Alert children and adults to the hazards of high...

Страница 9: ...on the ground fixer DD with the corresponding holes on the base E then insert the bolt on foot glider H into the holes and hand tighten them clockwise To prevent heater from strong wind or incline gr...

Страница 10: ...much to avoid the glass pieces being damaged See Figure 5 5 Insert the four wide glass C into the L clips which have been welded together with table top then attach them with bolts AA using the Phill...

Страница 11: ...ecure the cylinder by tightening clockwise the retention point found on the cylinder holder so that the cylinder cannot move from side to side or fall down Connect the regulator screw the black handle...

Страница 12: ...rol panel to access the battery compartment The ignitor module requires one AAA size battery BATTERY IS NOT INCLUDED OFF APG MAX M X 1 AAA 1 5V IGNITOR Encendedor ON MIN ENC M N LIGHTING INSTRUCTIONS...

Страница 13: ...in gas control knob slightly and turn to OFF To perform a leak test gas valve regulator hose connection Figure 13 inlet tube bellows connection Figure 14 Figure 15 gas control knob ignition button OFF...

Страница 14: ...vapors and liquids b Do not obstruct the flow of combustion and ventilation air c Keep the ventilation opening s of the cylinder enclosure free and clear from debris 3 Air flow must be unobstructed Ke...

Страница 15: ...and the cylinder is less than 1 4 full 1 2 There is dirt or film on the reflector and burner screen The burner is blocked 1 2 Wait until gas cylinder warms up and becomes unfrosted Clear the blockage...

Страница 16: ...7 606 2818 Questions problems missing parts Before returning to the store please contact our Customer Service service alphamarts com Heater Burner all mechanical parts and fittings to control panel an...

Отзывы: