Installing the MSC-4 

 

The Manual Speed Control must be installed by a qualified electrician.  

Before installing or servicing the Manual Speed Control, switch OFF the power supply at the source.  
Install the Manual Speed Control and all equipment connected to it according to local electrical codes. 

 

Mount the enclosures on a sheltered, vertical surface, with the electrical knockouts facing down. 
Use a screwdriver to tighten the screws in the enclosures. Do not use a drill or over tighten the screws; this 
can crack the enclosures and ruin the watertight seal. 

Use the electrical knockouts for bringing wires or cables into or out of the enclosures. Use watertight strain 
reliefs or conduit connectors at all cable-entry points. 

Do not make additional holes in the enclosures; this can damage the watertight seal or control components 

and void the warranty. 

Only permanent split capacitor motors appropriate for variable speed control, or shaded pole motors, 
can be used on the MSC-4.

 

 

1.

 

Mount the unit on a sheltered, vertical surface, with the electrical 
knockouts facing down. 

2.

 

Before removing electrical knockouts, remove the cover to prevent 
damaging the control.   

3.

 

Use watertight strain reliefs or conduit connectors at all cable entry 
points. 

4.

 

Connect the wires as shown. 

5.

 

Fasten the cover to the base of the control. 

 

 

Operation 

The MSC-4 is set at the factory for use with 230 VAC variable speed 
fans. To optimize the MSC-4 for 120 VAC variable speed fans, 120 VAC 
lamps, or a particular fan, see 

Setting the high/low limits

 on page 3. 

To use the MSC-4, place the power switch in the 

ON

 position and then 

adjust the control knob for the desired speed or output.  

 

Service

Panel 

120/230 VAC

Enclosure

D

Insulate using a 
#31 wire nut or 
similar connector.

 

Line/L1

Neutral/L2 

Fan/ 

Lamps 

15 A, 250 VAC ABC-type ceramic 

A

B

Caution: For controlling shaded-pole, permanent-split-capacitor, 
universal motors, or incandescent lamps only.

C

Connect all ground wires to the grounding terminal located near the 
cable entry points.

 

D

Use liquid-tight connectors at the cable entry points and seal with an 
RTV silicone.

 

E

Low limit

 

High

 

Low

 

Load

Caution: Destiné uniquement à la commande de moteurs universels, 
à bague de déphasage, à condensateur permanent, ou lumières 
incandesence seulement.

 

High limit

 

High

 

Low

 