Operating
Instructions
&
Parts
Manual
Horizontal
Rotary
Tables
Dividing
Plates
Pg.
8
Troubleshooting
Chart
Symptom
Possible
Cause(s)
Corrective
Action
Handwheel rotates:
Table does not rotate
1.Key(Ref.No.32) is missing
1. Insert Key
2. Worm Shaft disengaged
2. Engage worm shaft
(see operation)
Handwheel will not rotate
1.
Hold‐down clamps are
too tight
2. Lock nut too tight
(see maintenance)
3. Table need lubrication
1.
Loosen hold‐down clamps
2.
Adjust lock nut properly
3.
Lubricate properly
(see Maintenance)
Worm Shaft will not engage
Table
Eccentric sleeve cannot rotate
properly
Properly adjust threaded pin and
Set screw(see maintenance)
Worm
Gear
/
Eccentric
Sleeve
Adjustment
First Loosen Handle
A
for the eccentric sleeve lock and proceed to unscrew
Bolt B
.
Screw clockwise the
Limiting Bolt A
to adjust the mesh of the worm gear to the table top gear.
At this time, rotate the handle wheel clockwise and counterclockwise to ensure the mesh of the
worm gear is within 6° and then tighten the
Locking Bolt B
and then clamp the
Handle A
to
lock the eccentric sleeve.
Screw counterclockwise the
Limiting Bolt A
to reduce the mesh and proceed to rotate the
handwheel to ensure the mesh of the worm gear is within 6° and then tighten
Locking Bolt B.
Rotate the
Indicator
counterclockwise until the
Bolt C
is touching the
Locating Pin.
This
procedure has just disengaged the worm gear. Rotate the indicator clockwise until
Bolt D
is
touching
Bolt A.
Now the worm gear is engaged.