background image

careless or abnormal use;

Keep

the lamp

work

under the required

voltage

,

ensure

the use of

voltage is in the voltage range of technical parameters ;

For using the power line input and output connector,

the maximum of

lamps is 12 under the voltage 220V; the maximum of lamps is 6 under the

voltage 110V. The number of lamps for using the DMX512 input and output

signal line is not limited ;

Do not install the lights near the heat source to avoid the rising of

lamp temperature and affecting the normal use of lamps and lanterns,

even damaging the lamp;

Check before use the connection of 110V~220V AC power to ensure that

the connection

between power supply and switch is good. Please use

qualified power plug and outlet ;

During move and installation,

make sure the device not crashed with

metal parts and other tough materials .

2. Warning

Unqualified

person

involved

with

installation,

operation

and

maintenance of this lamp is prohibited

Don't insert other things into the inside of the lamp, so as to avoid

anything

reach ing the part with high voltage,

then lead to partial

short circuit , or else a fire or electric shock may occur , and then

affect the normal use of the product.

Please keep the bulb clean, do not direct ly touch the bulb glass by

hand.

Do not watch the light source straightly for avoid the damage to the

eyes.

9

Notes for installation and operation

1. Installation

1)Before the location and installation of the lamp, ensure the stability

of its installation point , which can hold at least 10 times the weight of

the lamp.

(2) Installation method: use one piece of professional clamp , M13 bolts,

and our own retaining screw to install; pull the safety chain( distribution

or owned)

through

the yoke

or

other

hanging

objects

and

tighten

the

fixation screw. Check if there is any wear of the safety chain and loosen

of the clamp periodically . In addition,

cut off the power supply when

remove the lamps to ensure safety . Take the safety rope first , then remove

the hanging, and pay attention to the safety of pedestrians below.

2. Notes:

1

Do not frequently switch the lamp, so as not to affect the service

life of the bulb. Try to avoid the lamp to run for long periods of time.

Содержание Sensation

Страница 1: ...Caution please read this user manual carefully before you initially start up LED CTC Panel Light User Manual LED CTC Panel Lighting Professional lighting equipment ...

Страница 2: ... Product data 4 4 Technical parameters 5 5 Dimension Mappings Pictures of fittings 6 6 Control system description 7 7 Operating instructions 8 8 Safety instructions 10 9 Notes for installation and operation 11 10 Comparison of common faults 12 ...

Страница 3: ... the customers 2 The troubles resulting from customer s careless or abnormal use 3 The improper installation and the incorrect voltage supply 4 The damage or faulty performance caused by misuse improper installation careless handling or where repairs have been attempted by others 5 The breakdown and the damage caused by the Force majeure 6 Without guarantee card Ilightings provide paid service for...

Страница 4: ... The product belongs to Ilightings registered company the intellectual property is exclusively reserved We will file a lawsuit on condition that it is illegally copied and imitated 2 Packing list This series of products supply standard carton packaging flight case can be supply for your requirement Do not extrude the plastic parts for avoiding any breaking or deformation When receiving the product...

Страница 5: ...orescent Lamp The double balance heat conduction technology and natural flow type heat dissipation design are used to export a greater flow of energy effectively with noise free 120 ultra beam angle ensure the large area diffused lighting and viewfinder It can be used as auxiliary lighting applications 4 Technical parameters Power supply AC90V 120V 200V 250V 50Hz 60Hz Light source Everlihgt brand ...

Страница 6: ...t barrier Four leaf supply for requirement Weight 3KG 5 Dimension Mappings Pictures of fittings Dimension 682x432x120MM Hanging installation screw holes can be installed 12MM Signal Cannon Power Connection Swiss Neutrik Power Con ...

Страница 7: ...er than 60 meters There must be signal amplifier when the length of wire is longer than 60 meters 2 Connection of the lamp signal line This LED lamp receive digital signal in DMX512 1900 format It can work in either the master or slaver mode under EDIT and self propelled mode The master slave mode also connects by DMX line Using the cylindrical 3 core XLP cable provided by the manufacturer connect...

Страница 8: ...red address Press ENTER to go to the next menu or confirm Press MEAU to return to previous menu To change the function please get to the bottom of the menu and press ENTER 3 Signal functional instruction MENU selection UP advance DOWN return ENTER confirmation 4 DMX IN DMX OUT DMX512 input and output connection 5 POWER IN POWER OUT input and output connection of power The characteristic of control...

Страница 9: ...e 1 to scene 10 B W Y The second color FADE Dimming delay Default 2 0 9 0 denotes stop the FADE 1 9 denotes rising delay TEMP Tempera ture control C 000 0 150 Current temperature t 065 Press ENTER for adjusting 0 150 Protected temperature VERSION Version informat ion Display the current software version Notes Before entering the screensaver beyond the non manual and scene editing mode the exclamat...

Страница 10: ... port of 2nd lamp then from the DMX output port of 2nd lamp to the DMX input port of 3rd lamp etc Until all the lamps are connected in a chain Finally insert the loop into the DMX input port of last lamp for complete the connection Choose the 1st lamp to function as the master and run it in the Self propelled Mode or EDIT mode other lamps will work as slaves with the same effect and run them in th...

Страница 11: ...mp so as to avoid anything reaching the part with high voltage then lead to partial short circuit or else a fire or electric shock may occur and then affect the normal use of the product Please keep the bulb clean do not directly touch the bulb glass by hand Do not watch the light source straightly for avoid the damage to the eyes 9 Notes for installation and operation 1 Installation 1 Before the ...

Страница 12: ...address code setting is correct 2 Check if the XLR signal line is destroyed Master slaver Mode the master work but the slaver not work 1 Confirm there is only one master connected without the DMX console others are in the slaver or address code mode 2 The Master Slave Mode has some problems Check for the connected line Keys not work Check if any of the keys does not reset Low light intensity brigh...