General Description and Operation
Manual System Description
The manual version has a water-in port and a water-out port. It fills the tank
underneath it with water. The user supplies their own pump to draw the water
from the unit.
Powered System Description
The powered version has two 12 volt pumps. At 25 amp each, the first pump is
used to push water through the membranes of all the cartridges to fill the pure
water tank. The second pump is used to supply a water fed pole and brush, or
for trigger rinsing. This unit consists of one 40” Carbon filter, one or two 40” RO
filter(s), one 40” DI filter. This unit has a power switch, a pressure gauge before
the filters and another pressure gauge for monitoring spray pressure.
General operation of Powered Pure Water Module:
1. Connect the raw water supply. Turn on water.
2. Fill the raw water tank (Powered and auto systems require buffer tank).
3. Turn power switch to number 1 in order to produce pure water to fill the pure
water storage tank.
4. Once the tank is filled to the desired level, turn the power switch to 2 to spray.
— You can make pure water WHILE ALSO spraying by turning the power
switch to 1 AND 2.
5. Use trigger sprayer to apply to desired surface, or supplu a water fed pole.
es
Auto System Description
The auto version has two 12 volt pumps with a digital controller. This unit is fully
automatic with bluetooth remote capabilities. The controller is custom designed to
make using this model as simple and easy as possible. This unit can be controlled
from as far away as 500 feet (300 feed through building and obtacles). The first
pump is used to push water through the membranes of all the cartridges to fill the
pure water tank. The second pump is uused to supply a water fed pole and brush, or
for trigger rinsing. This unit consists of one 40” carbon filter, two 40” RO filter(s), one
40” DI filter. This unit is specially designed for making pure water while spraying. It
can be configured to fill on demand or manually fill each time pure water is needed
(
see picture #1 and #2
).
General Operation of Automatic Pure water Module:
1. Connect the water supply. Turn on water.
2. Fill the raw water tank (Powered and auto systems require buffer tank).