11
Press enter to set. The next setting is Fill Delay.
Fdy is the time delay in minutes from the tank reaching full and the filling re-starting
should the water level drop. You can set this delay from 0-10 minutes with the up
and down buttons. Setting to ‘0’ turns the delay off. Press enter to set.
The next setting is Autoflush. Your controller has three Autoflush modes:
0 - Autoflush is off
1 - Repeat Autoflush every hour
2 - Autoflush just once at the start of filling
Select the required Autoflush mode with the up or down button. Then press enter to
move to the next item.
Set Up - Autoflush
,
,
Message
Description
Controller Messages An error has occured while using AutoCal.
This will happen when the motor is not connected or the enter
button has been pressed to cancel it.
Controller Messages This message will start to flash when the
battery is low (<11.0V). If the battery is below 10.5V the pump
will be disabled to protect the battery (unless low battery cutoff
is disabled*).
Controller Messages An over current has been detected, the
controller has shut down the pump to protect itself. Lower the
flow rate and check the hose for blockages.
Controller Messages A dead end has been detected. If this is not
the case, try increasing the calibration value.
Pressure switch has activated or the motor is disconnected.
CONTROLLER MESSAGES