Power Control Software Instructions

Overview

As indicated, the M1500-UPS-PFP software is designed for use with

Windows 95™, Windows 98™, Windows Me™, Windows NT™, Windows

2000™ and Windows XP™.  The computer’s operating system works in

conjunction with the UPS to provide full protection of professional

equipment (such as automation controllers, digital audio work stations

and small format digital consoles) and is equally effective for high–end

home theater use (such as digital video recorders, video projectors and

satellite networking).  

As far as the professional contractor, one can use the advanced options

and user interface to maintain complete power management (such as

the Data Recorder Log as a diagnostic tool).  In no way does this mean

the novice cannot understand the many advantages of M1500-UPS-PFP

software.  

This program may be used temporarily during the initial system setup.

An installer can use a notebook computer to set the variables within the

M1500-UPS-PFP software.  Once the setup is completed, the notebook

computer can be disconnected.  All settings are stored in the UPS.

The software can also be used to manage a Personal Computer.

Functionality is very similar to a standard UPS with a PC.  The UPS can

provide continued power to the PC to maintain recording capabilities if it

is being used as multimedia source or digital workstation. It is also

capable of saving open documents and shutting down the PC during

extended power failures.  This requires a permanent RS232 connection

to the PC and having the M1500-UPS-PFP software running in the back-

ground on the PC.  When a power failure occurs, open files are saved

under auto-assigned file names or existing file names and the files

closed.  The computer and UPS are automatically shut down to con-

serve battery power.  Files with auto-assigned names will be saved

under C:\PCTemp, where C is the name of your main hard drive.  Files

that have previously been saved will be saved in their original location.

There is also a Schedule feature that can automatically save and close

open files and then shut down the computer and UPS at a user specified

date and time as well as re-start the computer at a user specified date

and time.  Use of this feature is optional and is not required for the

power failure shutdown to occur.

Note:

The M1500-UPS-PFP software may not always be capable with

various recording software.  Please check your program requirements.

Running background software may affect the recording application’s

performance.  This will depend on the various user preferences available

in the multimedia device or digital workstation’s recording application.

The M1500-UPS-PFP is a true power management user interface.

2. Power Button:

Closes the program window.

3. Minimize Button:

Minimize the program window.

4. Setup Button:

Opens the Setup Window.

1. Log Button: 

Opens the Event Log Window.

6. Schedule Button:

Click this button to access the

Schedule Window.

5. Model:

Shows the model

of UPS that is being used.

7. Status Bar:

Displays messages

about the status of the software.

MAIN MENU

Содержание M1500-UPS-PFP

Страница 1: ...NSAFE VOLTAGE LINE FAULT POWER ON AVR MODE BATTERY MODE BATTERY LEVEL LOAD LEVEL The M1500 UPS PFP is a Programmable Uninterruptible Power Supply Voltage Regulator Power Conditioner INS00836 REV C 11 08 UNITED STATES PATENT I S P R O T ECTED BY PATENT NUM B E R S T E C H N O L OGY UTILIZED ON THIS P R O D U C T 7 245 470 ...

Страница 2: ...tions pg 12 RS232 Communications Protocol Command Set pgs 13 14 15 16 FCC Notice and Warranties pg 17 Table of Contents Before You Begin 2 Power Cord 1 UPS Unit 3 Phone Cord 5 Rack Mounting Kit 4 DB 9 Serial Cable 6 Power Control Software CD Inspect the UPS upon receipt In addition to this manual the box should contain the following UNPACKING POWER TEST MAX Home Cinema UPS Pure Sine Wave Intellige...

Страница 3: ...ve contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery No user serviceable parts inside except for the battery CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a component CAUTION DO ...

Страница 4: ...large electri cal demands e g refrigerator copier etc Avoid using exten sion cords If used the extension cord must be UL or CSA Listed minimum 14 AWG 3 wire grounded and rated for 15 Amps 5 Press the power switch to turn the UPS on The Power ON indicator light will illuminate 6 The rear panel circuit breakers will open and power to the con nected equipment will be turned OFF if an overload is dete...

Страница 5: ...uminate when the load is above 25 the 2nd above 50 and the 3rd above 75 The 4th arrow will flash when the load is between 85 and 100 Battery Level Indicator This is a visual indication of the battery charge If battery capac ity is under 25 no indicator LED will illuminate and UPS starts beeping if the audible alarm is enabled 3 USA Canada 800 472 5555 707 283 5900 Fax 707 283 5901 FRONT PANEL DISP...

Страница 6: ...nt to both outputs The IR LED s will flash once per second during the delay time and will stop flashing after the IR code is sent 2 If the delay settings are the same for both IR1 and IR2 the IR2 code will be sent to both outputs 2 seconds after IR1 3 The IR commands will also be transmitted immediately after the battery charge falls below the critical load battery threshold This ensures that equi...

Страница 7: ...continued Power Control Software The M1500 UPS PFP has one rear panel serial port that provides the ability to program special functions i e safely shutdown a PC application or integrate the UPS with a home automation system Use of the software is optional The communications protocol is open a programmer can write their own control program or integrate the UPS s programming control functions into ...

Страница 8: ...ndows Run command 12 Follow the on screen instructions 13 Once the software has finished installing remove the disk and restart your computer For Windows NT 4 0 1 Click on Start point to Settings then click Control Panel 2 Double click on the UPS Icon 3 Remove the check mark from the box labeled UPS is installed on 4 Click OK 5 Acknowledge the message that the UPS is in an unknown state 6 Exit to ...

Страница 9: ... and shutting down the PC during extended power failures This requires a permanent RS232 connection to the PC and having the M1500 UPS PFP software running in the back ground on the PC When a power failure occurs open files are saved under auto assigned file names or existing file names and the files closed The computer and UPS are automatically shut down to con serve battery power Files with auto...

Страница 10: ...tware 12 Time between power failure and shutdown For use with a PC This is the user control lable delay between when the power fails and the software starts the shutdown process If unchecked and plugged into one of the critical load outlets the PC will run on battery until the low battery signal is received 2 minutes of backup time remaining and then start the shutdown process 11 Time between powe...

Страница 11: ... of any scheduled startups and shutdowns 7 Delete Clears the selected item from the schedule 3 Turn Off Select the day date and time that you want the computer system to shutdown This is optional and has no effect on whether your computer will shut down during a power failure 5 Cancel Closes the window without saving any schedules even if one was added to the Schedule Display Window Does not can c...

Страница 12: ...UPS PFP 3 year warranty PF Power will replace M1500 UPS PFP batteries if they fail within the 3 year product warranty period For battery replacement information and instructions please contact Panamax Customer Service at www pana max com or call 800 472 5555 If batteries fail after the M1500 UPS PFP 3 year product warranty then the customer is responsible for battery replacement For detailed batte...

Страница 13: ... boost 13 of input voltage for output regulation while input voltage is from 8 to 15 under nominal AVR Max boost 26 of input voltage for output regulation while input voltage is from 15 to 26 under nominal AVR Max buck 15 of input voltage for output regulation while input voltage is from 8 to 26 over nominal Utility Failure The UPS is providing battery power to the connected equipment Utility Fail...

Страница 14: ... Lead acid___________________________________________________________________Yes User replaceable_____________________________________________________________Yes Typical recharge time _______________________________________________________8 hrs COMMUNICATION Software ___________________________________ Included Windows95 98 ME NT 2000 XP Hardware_______________________________________________ RS23...

Страница 15: ... outlets on and off to force a hard reboot of equipment Devices such as satellite receivers often crash and must be reset The following are commands made by the controller to the UPS AC INPUT BATTERY MAIN NCL To Non Critical Load NCL Outlets To Critical Load CL Outlets Stop bit _______________1 bit Parity ________________None Flow control ____________one Baud rate _______2400 bps Start bit _______...

Страница 16: ...space 20 Hex XX is a number between 25 and 60 represented in ASCII If XX is a valid number between 25 and 60 Action Assigns the battery threshold variable with the value XX Response from UPS BTHRESH SP XX CR If XX is not valid Action None Response from UPS INVALIDCMD CR Enable Audible Alarm It is important that the UPS be as quiet as possible as it will be located in a home theater environment It ...

Страница 17: ... is in AVR mode and bucking voltage by 11 Response from UPS AVRBUCK1 CR If the UPS is in BATTERY mode Response from UPS BATTERY CR Request Load Level Status Transmit the load level percentage Send to UPS LOADSTAT CR Response from UPS XX SP LOAD CR XX is the load percentage represented in ASCII Request Battery Charge Level Status Transmit the remaining battery charge percentage Send to UPS BATTERYS...

Страница 18: ...in AVR or BATTERY mode UPS is in AVR boosting 13 UPS is in AVR boosting 26 UPS is in AVR bucking 15 UPS is in BATTERY mode Battery charge falls below critical load threshold Input voltage exceeds high volt age failure t hold Input voltage falls below low voltage failure t hold Battery charge falls below critical load threshold Response from UPS NORMAL CR AVRBOOST1 CR AVRBOOST2 CR AVRBUCK1 CR BATTE...

Страница 19: ...l render the PFPower connected equipment protection policy null and void For additional information on how to protect your system please contact PFPower before connecting your equipment to the surge protector More detailed information is available at www pana max com or www furmansound com If you have any questions regarding these require ments please contact Customer Relations MODEL M1500 UPS PFP...

Страница 20: ...1690 Corporate Circle Petaluma CA 94954 Tel 707 283 5900 Fax 707 283 5901 www panamax com www furmansound com ...

Отзывы: