Troubleshooting

Technical Specifications

12

USA & Canada (800) 472-5555  •  (707) 283-5900  •  Fax (707) 283-5901

AC SPECIFICATIONS

CAPACITY
(VA)__________________________________________________________1500VA
(Watts)________________________________________________________1000W

INPUT
Voltage Range____________________________________________88Vac - 147Vac
Frequency Range______________________________________________47 - 63 Hz

OUTPUT
On Battery Output Voltage_____________________Pure Sine Wave at /- 5%
On Battery Output Frequency__________________________________ 60 Hz +/- 1%
Transfer Time_____________________________________________________ 4ms

PROTECTION & FILTRATION
On Utility____________________________________ Over/Under voltage protection
On Battery________________________________________ Internal Current Limiting
Patented Power Management Circuit____________________________________Yes
Overvoltage Shutoff ____________________________________________144V ±8V
Undervoltage Shutoff  ___________________________________________ 90V ±6V
Thermal Fusing____________________________________________________Yes
Protection Modes __________________________________________L-N, L-G, N-G
Response Time ___________________________________________________ < 1 n
Single Pulse Energy Dissipation_________________________________1650 Joules
EMI/RFI Noise Filtration______________________________50dB (100kHz – 1 MHz)

TELCO PROTECTION

Fuseless/Auto-Resettable_____________________________________________Yes
Clamping Level___________________________________________________ 260V
Capacitance _____________________________________________ 30 pf (approx.)
Suppression Modes_________________________________  Metallic & Longitudinal
Wires Protected_______________________________________2 wire, 1 pair (4 & 5)
Connectors______________________________________RJ-11/45 Shared with LAN

LAN PROTECTION

Compatibility___________________________________________________________10/100bT 
Clamping Level_______________________________________________________________7V
Suppression Modes_____________________________________Differential & Common Ground
Wires Protected____________________________________________________Pins 1, 2, 3, & 6
Connectors______________________________________________RJ/11-45 Shared with Telco

BATTERY

Sealed____________________________________________________________________Yes 
Maintenance-free____________________________________________________________Yes
Lead acid___________________________________________________________________Yes  
User replaceable_____________________________________________________________Yes
Typical recharge time _______________________________________________________8 hrs.

COMMUNICATION

Software ___________________________________ Included (Windows95/98/ME/NT/2000/XP)
Hardware_______________________________________________ RS232 (open command set)
Programmable IR_________________(learning) sends IR signals to equipment after power failure

PHYSICAL

Rack Mountable_________________________________________Yes (rack mount kit included)
Maximum Dimensions_____________________________________________17"  x  3.5  x  15.3"
Weight (lbs.)________________________________________________________________ 59
Outlets______________________________________________ 6 Total (2 assigned critical load)

GENERAL

Lightning protection __________________________________________________________Yes
Product Warranty_________________________________________________________ 3 Years

Design and specifications subject to change without notice due to product improvement.

Problem

Outlets do not provide power to
equipment.

The UPS does not perform to
expected runtime.

The UPS will not turn on.

Software is inactive.

Possible Cause

Circuit breaker is tripped due to overload

Batteries are discharged.

Unit has been damaged by a surge or spike.

Battery is not fully charged.

Battery is slightly worn out.

The on/off switch is designed to prevent damage by rapidly
turning it off and on.

The unit is not connected to an AC outlet.

The battery is worn out.

Mechanical problem.

The serial cable is not connected.

The serial cable is connected to the wrong port.

The unit is not providing battery power

The serial cable is not the cable that was provided with the unit.

Solution

Turn the UPS off and unplug at least one piece of equipment.  
Wait 10 seconds, reset the circuit breaker and then turn the UPS on.

Recharge the unit for at least 4 hours.

Recharge the battery by leaving the UPS plugged in.

Recharge the battery by leaving the UPS plugged in.

Contact Panamax about replacement batteries.

Turn the UPS off. Wait 10 seconds and then turn the UPS on.

The unit must be connected to a 110/120v 60Hz outlet.

Contact Panamax about replacement batteries.

Contact Panamax.

Connect the serial cable to the UPS unit and an open serial port of
your computer. You must use the cable included with the unit.

Try another serial port on your computer.

Shut down your computer and turn the UPS off.  Wait 10 seconds and
turn the UPS on.  This should reset the unit.

You must use the cable included with the unit for the software.

Содержание M1500-UPS-PFP

Страница 1: ...NSAFE VOLTAGE LINE FAULT POWER ON AVR MODE BATTERY MODE BATTERY LEVEL LOAD LEVEL The M1500 UPS PFP is a Programmable Uninterruptible Power Supply Voltage Regulator Power Conditioner INS00836 REV C 11 08 UNITED STATES PATENT I S P R O T ECTED BY PATENT NUM B E R S T E C H N O L OGY UTILIZED ON THIS P R O D U C T 7 245 470 ...

Страница 2: ...tions pg 12 RS232 Communications Protocol Command Set pgs 13 14 15 16 FCC Notice and Warranties pg 17 Table of Contents Before You Begin 2 Power Cord 1 UPS Unit 3 Phone Cord 5 Rack Mounting Kit 4 DB 9 Serial Cable 6 Power Control Software CD Inspect the UPS upon receipt In addition to this manual the box should contain the following UNPACKING POWER TEST MAX Home Cinema UPS Pure Sine Wave Intellige...

Страница 3: ...ve contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery No user serviceable parts inside except for the battery CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a component CAUTION DO ...

Страница 4: ...large electri cal demands e g refrigerator copier etc Avoid using exten sion cords If used the extension cord must be UL or CSA Listed minimum 14 AWG 3 wire grounded and rated for 15 Amps 5 Press the power switch to turn the UPS on The Power ON indicator light will illuminate 6 The rear panel circuit breakers will open and power to the con nected equipment will be turned OFF if an overload is dete...

Страница 5: ...uminate when the load is above 25 the 2nd above 50 and the 3rd above 75 The 4th arrow will flash when the load is between 85 and 100 Battery Level Indicator This is a visual indication of the battery charge If battery capac ity is under 25 no indicator LED will illuminate and UPS starts beeping if the audible alarm is enabled 3 USA Canada 800 472 5555 707 283 5900 Fax 707 283 5901 FRONT PANEL DISP...

Страница 6: ...nt to both outputs The IR LED s will flash once per second during the delay time and will stop flashing after the IR code is sent 2 If the delay settings are the same for both IR1 and IR2 the IR2 code will be sent to both outputs 2 seconds after IR1 3 The IR commands will also be transmitted immediately after the battery charge falls below the critical load battery threshold This ensures that equi...

Страница 7: ...continued Power Control Software The M1500 UPS PFP has one rear panel serial port that provides the ability to program special functions i e safely shutdown a PC application or integrate the UPS with a home automation system Use of the software is optional The communications protocol is open a programmer can write their own control program or integrate the UPS s programming control functions into ...

Страница 8: ...ndows Run command 12 Follow the on screen instructions 13 Once the software has finished installing remove the disk and restart your computer For Windows NT 4 0 1 Click on Start point to Settings then click Control Panel 2 Double click on the UPS Icon 3 Remove the check mark from the box labeled UPS is installed on 4 Click OK 5 Acknowledge the message that the UPS is in an unknown state 6 Exit to ...

Страница 9: ... and shutting down the PC during extended power failures This requires a permanent RS232 connection to the PC and having the M1500 UPS PFP software running in the back ground on the PC When a power failure occurs open files are saved under auto assigned file names or existing file names and the files closed The computer and UPS are automatically shut down to con serve battery power Files with auto...

Страница 10: ...tware 12 Time between power failure and shutdown For use with a PC This is the user control lable delay between when the power fails and the software starts the shutdown process If unchecked and plugged into one of the critical load outlets the PC will run on battery until the low battery signal is received 2 minutes of backup time remaining and then start the shutdown process 11 Time between powe...

Страница 11: ... of any scheduled startups and shutdowns 7 Delete Clears the selected item from the schedule 3 Turn Off Select the day date and time that you want the computer system to shutdown This is optional and has no effect on whether your computer will shut down during a power failure 5 Cancel Closes the window without saving any schedules even if one was added to the Schedule Display Window Does not can c...

Страница 12: ...UPS PFP 3 year warranty PF Power will replace M1500 UPS PFP batteries if they fail within the 3 year product warranty period For battery replacement information and instructions please contact Panamax Customer Service at www pana max com or call 800 472 5555 If batteries fail after the M1500 UPS PFP 3 year product warranty then the customer is responsible for battery replacement For detailed batte...

Страница 13: ... boost 13 of input voltage for output regulation while input voltage is from 8 to 15 under nominal AVR Max boost 26 of input voltage for output regulation while input voltage is from 15 to 26 under nominal AVR Max buck 15 of input voltage for output regulation while input voltage is from 8 to 26 over nominal Utility Failure The UPS is providing battery power to the connected equipment Utility Fail...

Страница 14: ... Lead acid___________________________________________________________________Yes User replaceable_____________________________________________________________Yes Typical recharge time _______________________________________________________8 hrs COMMUNICATION Software ___________________________________ Included Windows95 98 ME NT 2000 XP Hardware_______________________________________________ RS23...

Страница 15: ... outlets on and off to force a hard reboot of equipment Devices such as satellite receivers often crash and must be reset The following are commands made by the controller to the UPS AC INPUT BATTERY MAIN NCL To Non Critical Load NCL Outlets To Critical Load CL Outlets Stop bit _______________1 bit Parity ________________None Flow control ____________one Baud rate _______2400 bps Start bit _______...

Страница 16: ...space 20 Hex XX is a number between 25 and 60 represented in ASCII If XX is a valid number between 25 and 60 Action Assigns the battery threshold variable with the value XX Response from UPS BTHRESH SP XX CR If XX is not valid Action None Response from UPS INVALIDCMD CR Enable Audible Alarm It is important that the UPS be as quiet as possible as it will be located in a home theater environment It ...

Страница 17: ... is in AVR mode and bucking voltage by 11 Response from UPS AVRBUCK1 CR If the UPS is in BATTERY mode Response from UPS BATTERY CR Request Load Level Status Transmit the load level percentage Send to UPS LOADSTAT CR Response from UPS XX SP LOAD CR XX is the load percentage represented in ASCII Request Battery Charge Level Status Transmit the remaining battery charge percentage Send to UPS BATTERYS...

Страница 18: ...in AVR or BATTERY mode UPS is in AVR boosting 13 UPS is in AVR boosting 26 UPS is in AVR bucking 15 UPS is in BATTERY mode Battery charge falls below critical load threshold Input voltage exceeds high volt age failure t hold Input voltage falls below low voltage failure t hold Battery charge falls below critical load threshold Response from UPS NORMAL CR AVRBOOST1 CR AVRBOOST2 CR AVRBUCK1 CR BATTE...

Страница 19: ...l render the PFPower connected equipment protection policy null and void For additional information on how to protect your system please contact PFPower before connecting your equipment to the surge protector More detailed information is available at www pana max com or www furmansound com If you have any questions regarding these require ments please contact Customer Relations MODEL M1500 UPS PFP...

Страница 20: ...1690 Corporate Circle Petaluma CA 94954 Tel 707 283 5900 Fax 707 283 5901 www panamax com www furmansound com ...

Отзывы: