7IGXMSR`
':ERH(':7IVMIW``6IZ)``IQEMPGEVXWIVZMGI$TƽS[GSQ
Section 11 |
User Errors, System Faults,
and Warnings
PFlow Industries, Inc.
P 414 352 9000
F 414 352 9002
6720 N. Teutonia Ave.
Milwaukee, WI 53209
7]WXIQ*EYPXWGSRXMRYIH
*EYPX
4SWWMFPI'EYWI
7SPYXMSR
'SQQIRXW
Discharge Area Chain
Monitor Fault
(the chain
monitor limit switch at the
discharge area sprocket has
tripped)
The limit switch is
misaligned.
Contact maintenance.
Realign the limit switch.
Reset the system.
Limit switch maintenance
must be performed by
authorized personnel only!
The limit switch is damaged. Contact PFlow Industries,
Inc. Parts & Service for
replacement components.
Replacement components
must be replaced by
authorized personnel only!
There is a mechanical
problem with the drive chain.
Contact PFlow Industries,
Inc. Parts & Service.
Chain Take-up Minimum
Travel Fault
(the chain
take-up in the lower pit
has reached its minimum
allowable travel)
The limit switch is
misaligned.
Contact maintenance.
Realign the limit switch.
Reset the system.
Limit switch maintenance
must be performed by
authorized personnel only!
The limit switch is damaged. Contact PFlow Industries,
Inc. Parts & Service for
replacement components.
Replacement components
must be replaced by
authorized personnel only!
There is a mechanical
problem with the drive chain.
Contact PFlow Industries,
Inc. Parts & Service.
Chain Take-up Maximum
Travel Fault
(the chain
take-up in the lower pit
has reached its maximum
allowable travel)
The limit switch is
misaligned.
Contact maintenance.
Realign the limit switch.
Reset the system.
Limit switch maintenance
must be performed by
authorized personnel only!
The limit switch is damaged. Contact PFlow Industries,
Inc. Parts & Service for
replacement components.
Replacement components
must be replaced by
authorized personnel only!
The chain has stretched.
At least one link must be
removed from the drive
chain.
Contact PFlow Industries,
Inc. Parts & Service.
Chain has stretched to the
maximum allowable length.
Cartveyor® operation is
stopped until a link of
chain is removed to prevent
damage to the Cartveyor®
conveyor sections and chain
components.
There is a mechanical
problem with the drive chain.
Contact PFlow Industries,
Inc. Parts & Service.
Chain Take-up Mid Travel
(the chain take-up in the
lower pit has reached the
approximate middle of its
allowable travel)
The limit switch is
misaligned.
Contact maintenance.
Realign the limit switch.
Reset the system.
Limit switch maintenance
must be performed by
authorized personnel only!
The limit switch is damaged. Contact PFlow Industries,
Inc. Parts & Service.
The chain has stretched.
At least one link must be
removed from the drive
chain.
Contact PFlow Industries,
Inc. Parts & Service.
Although the Cartveyor®
will continue to run, contact
PFlow Industries, Inc.
Parts & Service to make
arrangements for the chain
to be shortened.