Section 11 |
User Errors, System Faults,
and Warnings
PFlow Industries, Inc.
P 414 352 9000
F 414 352 9002
6720 N. Teutonia Ave.
Milwaukee, WI 53209
9WIV*EYPXWGSRXMRYIH
*EYPX
4SWWMFPI'EYWI
7SPYXMSR
'SQQIRXW
Discharge Area Emergency
Stop Pressed
The discharge area
emergency stop push-
button was accidently
pressed.
Make sure the Cartveyor®
is free of damage and
people are not in the
Cartveyor®.
Pull out the emergency stop
push-button.
Press the safety relay reset
push-button.
Reset the system.
The discharge area
emergency stop push-
button was pressed to
prevent possible injury to
people or damage to the
Cartveyor®.
Determine how to properly
correct the situation.
Pull out the emergency stop
push-button.
Press the safety relay reset
push-button.
Reset the system.
Evaluation and correction
of the situation must be
performed by authorized
personnel only!
The discharge area
emergency stop push-
button was pressed due to
injury to people or damage
to the Cartveyor®.
Determine how to properly
correct the situation.
Pull out the emergency stop
push-button.
Press the safety relay reset
push-button.
Reset the system.
Evaluation and correction
of the situation must be
performed by authorized
personnel only!
The discharge area
emergency stop push-
button is defective.
Contact PFlow Industries,
Inc. Parts & Service for
replacement components.
Replacement components
must be replaced by
authorized personnel only!